Evidence map›Paper›PMID 39328652›Full record

ArticleCureus2024

Gastric Tube Insertion Performance of Second-Generation Supraglottic Airway Devices: A Prospective Manikin Study With Literature Review.

Yoshiya Adachi, Mineto Kamata, Akira Kitamura

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yoshiya AdachiDepartment of Anesthesiology, Saitama Medical University International Medical Center, Saitama, JPN.
Mineto KamataDepartment of Anesthesiology, Saitama Medical University International Medical Center, Saitama, JPN.
Akira KitamuraDepartment of Anesthesiology, Saitama Medical University International Medical Center, Saitama, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSecond-generation supraglottic airway devices (SGAs) are pivotal in airway management, with the ability to accommodate gastric tube (GT) insertion. However, research on GT insertion with SGAs under controlled conditions is limited. This study aimed to evaluate the GT insertion performance of SGAs using a manikin.

methodsThis prospective study included 32 anesthesiologists in our department, each with more than two years of clinical experience. These anesthesiologists randomly inserted four second-generation SGAs, including i-gel (Intersurgical Ltd., Berkshire, UK), Ambu AuraGain (Ambu, Copenhagen, Denmark), LMA ProSeal (Teleflex Medical, Wayne, PA), and LMA Supreme (Teleflex Medical), all of size 4, into a manikin, followed by GT insertion using Salem Sump™ tubes (Cardinal Health, Dublin, OH) (12 Fr for i-gel and 14 Fr for others) until the GT was 55 cm deep at the port entrance. The primary outcome was the difference in GT insertion time, with participants' evaluations. The usual use of second-generation SGAs, including GT insertion, was also surveyed. The differences in GT insertion time among the four SGAs were analyzed using the Friedman test, followed by the Bonferroni method for post-hoc analysis. P < 0.05 was considered significant.

resultsThe median GT insertion times were 17.2 seconds for i-gel, 9.9 seconds for AuraGain, 18.8 seconds for ProSeal, and 8.9 seconds for Supreme. These times showed significant differences (p < 0.001). Post-hoc analysis revealed that both Supreme and AuraGain had significantly shorter insertion times than i-gel and ProSeal, respectively (p < 0.001). Of the participants, 59% (19/32) evaluated Supreme as the easiest SGA for GT insertion, which is consistent with the observed insertion times. i-gel was the most frequently used SGA, chosen by 72% (23/32) of participants. Additionally, 72% (23/32) of anesthesiologists inserted GTs less than half as often following second-generation SGA placement.

conclusionsSignificant differences in GT insertion performance were found among the four second-generation SGAs. According to a survey of participants, second-generation SGAs were often used without GT insertion. Although the differences between products may not be clinically significant, selecting an SGA with easy GT insertion may improve the efficiency and reliability of gastric content drainage and enhance the safety of airway management when using SGAs.

Indexed as

ambu auragaingastric tubei-gellma proseallma-supremesecond-generation supraglottic airway devices

Identifiers

PMID39328652
PMCPMC11424386

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.