Evidence map›Paper›PMID 39327718›Full record

ArticleUltrasonography (Seoul, Korea)2024

Diagnostic value of transvaginal contrast-enhanced ultrasound in identifying benign and malignant endometrial lesions and assessing myometrial invasion.

Fang Guo, Yulin Yan, Chengsheng Huang, Xia Wang, Xing Wu, Yanli Xu, Tao Ying

Abstract read
In one paragraph

Article in Ultrasonography (Seoul, Korea), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fang GuoDepartment of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Yulin YanDepartment of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Chengsheng HuangDepartment of Gynecology and Obstetrics,Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Xia WangDepartment of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Xing WuDepartment of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Yanli XuDepartment of Gynecology and Obstetrics,Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.
Tao YingDepartment of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, shanghai, China.

Funding

Shanghai Sixth People's Hospital ynhg202010
6 · The paper itself

Abstract

purposeThe objective of this study was to evaluate the diagnostic value of transvaginal contrastenhanced ultrasound (CEUS) in differentiating benign from malignant endometrial lesions and assessing the extent of myometrial invasion.

methodsA total of 70 patients who underwent surgery for endometrial lesions at the authors' hospital were selected. Transvaginal ultrasound examination and CEUS were performed for quantitative and qualitative analysis. Based on the CEUS results, an International Federation of Gynecology and Obstetrics (FIGO) disease grade was assigned and compared with pathological findings.

resultsPostmenopausal vaginal bleeding is a key clinical manifestation of endometrial carcinoma. Among the patients with endometrial carcinoma, compared with normal myometrium, the lesion areas exhibited a greater rate of rise (defined as enhanced intensity divided by enhancement time) and a shorter half-clearance time (P<0.05). These findings suggest that in endometrial carcinoma, the contrast agent displays a "fast-in/fast-out/hyperenhancement" perfusion pattern. In contrast, the characteristic perfusion pattern for benign endometrial lesions is low enhancement (P<0.05). The diagnostic accuracy of CEUS in detecting myometrial invasion was 88% (22 of 25 cases).

conclusionTransvaginal CEUS is a practical and effective diagnostic imaging method for distinguishing between benign and malignant endometrial lesions. It can also be used to evaluate the depth of myometrial invasion in patients with early-stage endometrial carcinoma.

Indexed as

Contrast-enhanced ultrasoundEndometrial benign lesionsEndometrial neoplasmsMyometrial invasion

Identifiers

PMID39327718
PMCPMC11532519

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.