[Simultaneous determination of 102 synthetic cannabinoids in electronic cigarette oil by liquid chromatography-tandem mass spectrometry].
Article in Se pu = Chinese journal of chromatography, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- [Determination of 65 synthetic cannabinoids in whole blood by QuEChERS-ultra performance liquid chromatography- mass spectrometry].Se pu = Chinese journal of chromatography · 2026Article
- [Determination of caffeine and taurine in electronic cigarette oil by high performance liquid chromatography- tandem mass spectrometry].Se pu = Chinese journal of chromatography · 2025Article
- [Simultaneous determination of 38 indazole amides synthetic cannabinoids and 15 metabolites in wastewater by solid phase extraction-liquid chromatography-tandem mass spectrometry].Se pu = Chinese journal of chromatography · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Synthetic cannabinoids (SCs), which are among the most widely abused new psychoactive substances, are much more potent and have greater efficacy than natural cannabis. SCs can be disguised in various ways and are commonly sold in the form of electronic cigarette oil. SCs belong to a large family with structures consisting of a core with substituents, linker, ring with substituents, and tail. New SCs can be developed by adding substituents, such as halogen, alkyl, and alkoxy groups, to the aromatic ring system or by changing the alkyl chain length. Since the emergence of so-called first-generation SCs, subsequent developments have led to eighth-generation indole/indazole amide-based SCs. As of July 1, 2021, the entire category of SCs was added to the list of controlled substances, but implementation requires urgent improvements in detection technologies. Typically, each method is limited to a few SCs. Owing to the vast number of chemically diverse SCs and their fast update speed, the determination and identification of various types of SCs using a single method is challenging. Therefore, rapid, sensitive, and accurate quantitative methods that includes various types of SCs must be developed to meet the demand for the qualitative and quantitative analysis of new SCs in seized electronic cigarette oil. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of 102 SCs in electronic cigarette oil. The mass spectrometry and liquid-phase conditions influencing SC separation and determination were optimized. Using the external standard method, 102 SCs were successfully identified in electronic cigarette oil. The samples were extracted using methanol. Target analytes were separated on a Shimadzu Shim-pack GIST-HP C18 AQ column (100 mm×2.1 mm, 1.9 μm) at a column temperature of 40 ℃. The mobile phases consisted of (A) 0.1% formic acid aqueous solution and (B) methanol-acetonitrile (1∶1, v/v). The gradient elution conditions were as follows: 0-8 min, 55%A-15%A; 8-15 min, 15%A; 15-16 min, 15%A-55%A; 16-18 min, 55%A. The flow rate was 0.4 mL/min and the injection volume was 1 μL. Operating in the multiple reaction monitoring mode, the 102 SCs were identified within 18 min. Each SC exhibited a good linear relationship in the range of 1-100.0 μg/L with a correlation coefficient (