Evidence map›Paper›PMID 39327456›Full record

ArticleMicrosystems & nanoengineering2024

A piezoresistive-based 3-axial MEMS tactile sensor and integrated surgical forceps for gastrointestinal endoscopic minimally invasive surgery.

Cheng Hou, Huxin Gao, Xiaoxiao Yang, Guangming Xue, Xiuli Zuo, Yanqing Li, Dongsheng Li, Bo Lu, Hongliang Ren, Huicong Liu and 1 more

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Cheng HouSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China.
Huxin GaoDepartment of Electronic Engineering, The Chinese University of Hong Kong (CUHK), Hong Kong, China.
Xiaoxiao YangDepartment of Gastroenterology, Qilu Hospital, Shandong University, Jinan, Shandong, China.
Guangming XueSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China.
Xiuli ZuoDepartment of Gastroenterology, Qilu Hospital, Shandong University, Jinan, Shandong, China.
Yanqing LiDepartment of Gastroenterology, Qilu Hospital, Shandong University, Jinan, Shandong, China.
Dongsheng LiSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China.
Bo LuSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China. blu@suda.edu.cn.ORCID http://orcid.org/0000-0002-2858-1121
Hongliang RenDepartment of Electronic Engineering, The Chinese University of Hong Kong (CUHK), Hong Kong, China.
Huicong LiuSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China. hcliu078@suda.edu.cn.ORCID http://orcid.org/0000-0003-3651-9114
Lining SunSchool of Mechanical and Electrical Engineering, Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China. lnsun@hit.edu.cn.

Funding

National Natural Science Foundation of China (National Science Foundation of China) 62203315Natural Science Foundation of Jiangsu Province (Jiangsu Provincial Natural Science Foundation) BK20220490
6 · The paper itself

Abstract

In robotic-assisted surgery (RAS), traditional surgical instruments without sensing capability cannot perceive accurate operational forces during the task, and such drawbacks can be largely intensified when sophisticated tasks involving flexible and slender arms with small end-effectors, such as in gastrointestinal endoscopic surgery (GES). In this study, we propose a microelectromechanical system (MEMS) piezoresistive 3-axial tactile sensor for GES forceps, which can intuitively provide surgeons with online force feedback during robotic surgery. The MEMS fabrication process facilitates sensor chips with miniaturized dimensions. The fully encapsulated tactile sensors can be effortlessly integrated into miniature GES forceps, which feature a slender diameter of just 3.5 mm and undergo meticulous calibration procedures via the least squares method. Through experiments, the sensor's ability to accurately measure directional forces up to 1.2 N in the Z axis was validated, demonstrating an average relative error of only 1.18% compared with the full-scale output. The results indicate that this tactile sensor can provide effective 3-axial force sensing during surgical operations, such as grasping and pulling, and in ex vivo testing with a porcine stomach. The compact size, high precision, and integrability of the sensor establish solid foundations for clinical application in the operating theater.

Identifiers

PMID39327456
PMCPMC11427553

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.