Evidence map›Paper›PMID 39326885›Full record

ArticleAJNR. American journal of neuroradiology2025

Performance of Automated Algorithm in Large and Medium Vessel Occlusion Detection: A Real-World Experience.

Aakanksha Sriwastwa, Yasmin N Aziz, Kara Weiss, Robert Buse, Bin Zhang, Stacie L Demel, Arafat Ali, Sriharsha Voleti, Lily Li-Li Wang, Achala S Vagal

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Current state and advancements of imaging in acute ischemic stroke: a practical review.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2025
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Aakanksha SriwastwaFrom the Department of Radiology (A.S., L.L.-L.W., A.S.V.), University of Cincinnati Medical Center, Cincinnati, Ohio sriwasaa@ucmail.uc.edu.
Yasmin N AzizDepartment of Neurology and Rehabilitation Medicine (Y.N.A., S.L.D.), University of Cincinnati Medical Center, Cincinnati, Ohio.
Kara WeissUniversity of Cincinnati College of Medicine (K.W., R.B., B.Z.), Cincinnati, Ohio.
Robert BuseUniversity of Cincinnati College of Medicine (K.W., R.B., B.Z.), Cincinnati, Ohio.
Bin ZhangUniversity of Cincinnati College of Medicine (K.W., R.B., B.Z.), Cincinnati, Ohio.ORCID 0000-0003-0607-1806
Stacie L DemelDepartment of Neurology and Rehabilitation Medicine (Y.N.A., S.L.D.), University of Cincinnati Medical Center, Cincinnati, Ohio.
Arafat AliDepartment of Diagnostic Radiology (A.A.), Henry Ford Medical Center, Ann Arbor, Michigan.
Sriharsha VoletiDepartment of Diagnostic Radiology (S.V.), University of Pennsylvania, Philadelphia, Pennsylvania.
Lily Li-Li WangFrom the Department of Radiology (A.S., L.L.-L.W., A.S.V.), University of Cincinnati Medical Center, Cincinnati, Ohio.
Achala S VagalFrom the Department of Radiology (A.S., L.L.-L.W., A.S.V.), University of Cincinnati Medical Center, Cincinnati, Ohio.ORCID 0000-0001-6428-6499

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeFast, accurate detection of large (LVO) and medium vessel occlusion (MeVO) is critical for triage and management of acute ischemic stroke. Multiple artificial intelligence (AI)-based software programs are available commercially for automated detection and rapid prioritization of LVO. However, their ability, strengths, and limitations for detection of acute vessel occlusion in the context of expanding indications for mechanical thrombectomy are not entirely understood. We aimed to investigate the performance of a fully automated commercial detection algorithm to detect large and medium vessel occlusions in code stroke patients. MATERIALS AND

methodsWe utilized a single-center, institutional, retrospective registry of all consecutive code stroke patients with CTA and automated processing by using Viz.ai presenting at a large comprehensive stroke center between March 2020 and February 2023. LVO was categorized as anterior LVO (aLVO), defined as occlusion of the intracranial ICA or M1-MCA, and posterior LVO (pLVO), defined as occlusion of the basilar artery or V4-vertebral artery. MeVO was defined as occlusion of the M2-MCA, A1/A2-anterior cerebral artery, or P1/P2-posterior cerebral artery. We compared the accuracy of Viz.ai by using STARD guidelines. Radiology reports from 12 board-certified radiologists were considered the reference standard. Our primary outcome was assessing accuracy of the automated software for aLVO. Our secondary outcome was assessing accuracy for 3 additional categories: all LVO (aLVO and pLVO), aLVO with M2-MCA, and aLVO with MeVO.

resultsOf 3590 code stroke patients, 3576 were technically sufficient for analysis by the automated software (median age 67 years; 51% women; 68% white), of which 616 (17.2%) had vessel occlusions. The respective sensitivity and specificity for our prespecified categories were: aLVO: 91% (87-94%), 93% (92-94%); all LVO: 73% (68-77%), 92% (91-93%); aLVO + M2-MCA occlusion: 74% (70-78%), 93% (92-94%); and aLVO + all MeVO: 65% (61-69%), 93% (92-94%).

conclusionsThe automated algorithm demonstrated high accuracy in identifying anterior LVO with lower performance for pLVO and MeVO. It is crucial for acute stroke teams to be aware of the discordance between automated algorithm results and true rates of LVO and MeVO for timely diagnosis and triage.

Indexed as

AlgorithmsCerebral AngiographyComputed Tomography AngiographyIschemic StrokeAgedAged, 80 and overArtificial IntelligenceFemaleHumansMaleMiddle AgedRegistriesRetrospective Studies

Identifiers

PMID39326885
PMCPMC11979808

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.