ArticleArtificial organs2025

Impact of extracorporeal blood pump gap sizes on the performance and hemocompatibility under off-design operation.

Lars Fischer, Sebastian V Jansen, Ulrich Steinseifer, Ifan Yen, Po-Lin Hsu, Michael Neidlin

Abstract read
In one paragraph

Article in Artificial organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lars FischerDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.ORCID https://orcid.org/0009-0007-3278-040X
Sebastian V JansenDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Ulrich SteinseiferDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Ifan YenmagAssist Co., Ltd., Suzhou, China.
Po-Lin HsumagAssist Co., Ltd., Suzhou, China.
Michael NeidlinDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.

Funding

magAssist Co., Ltd
6 · The paper itself

Abstract

backgroundHemocompatibility remains the dominant challenge in rotary blood pumps, and more information on the relationship between individual pump design features, hemodynamics, and blood trauma in various operation conditions is necessary. The study evaluated the variation of gap sizes in extracorporeal blood pumps concerning their influence on blood compatibility, particularly during off-design conditions.

methodsWe developed a parametric generic blood pump framework for in-silico and in-vitro design feature analysis. Thirty-six designs with varying axial and radial gap sizes between 0.5 mm and 3 mm were generated. CFD was applied to calculate and compare device hemodynamics and evaluate the performance and hemocompatibility during off-design and target operation conditions. The following quantities were analyzed: pressure difference, hemolysis potential, residence times, hydraulic efficiency, and recirculation ratio.

resultsThe in-vitro prototype showed excellent agreement with in-silico predictions regarding hydraulic performance (R

conclusionsWe introduced and showed the feasibility of a parametric rotary blood pump framework to systematically investigate design feature impact. Results suggest, larger and uniformly sized gaps being overall beneficial regarding hemocompatibility.

Indexed as

Heart-Assist DevicesComputer SimulationEquipment DesignHemodynamicsHemolysisHumansHydrodynamicsMaterials TestingModels, CardiovascularProsthesis Designblood damageblood pumpCFDgapsoff design

Identifiers

PMID39324509
PMCPMC11848989

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.