Evidence map›Paper›PMID 39324129›Full record

ArticleJournal of magnetic resonance open2024

Fast quantitative MRI: Spiral Acquisition Matching-Based Algorithm (SAMBA) for Robust T

Mireia Perera-Gonzalez, Christina J MacAskill, Heather A Clark, Chris A Flask

Abstract read
In one paragraph

Article in Journal of magnetic resonance open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mireia Perera-GonzalezDepartment of Bioengineering, Northeastern University, Boston MA, USA.
Christina J MacAskillDepartment of Radiology, Case Western Reserve University, Cleveland OH, USA.
Heather A ClarkSchool of Biological and Health Systems Engineering, Arizona State University, Tempe AZ, USA.
Chris A FlaskDepartment of Radiology, Case Western Reserve University, Cleveland OH, USA.

Funding

MEDICAL SCIENTIST TRAINING PROGRAMT32GM007250 · NIGMS · CASE WESTERN RESERVE UNIVERSITY · PI HUANG, ALEX YEE-CHEN · 1985 to 2023
$33.4M
Medical Scientist Training Program at Case Western Reserve UniversityT32GM152319 · NIGMS · CASE WESTERN RESERVE UNIVERSITY · PI Heather Broihier, Alex Yee-Chen Huang · 2024 to 2026
$5.1M
Magnetic Resonance Fingerprinting of Tumor Vascular Perfusion and AcidosisR01CA269354 · NCI · CASE WESTERN RESERVE UNIVERSITY · PI Christopher A Flask, Mark David Pagel · 2023 to 2026
$2.6M
AChMRNS: Nanosensors for Chemical Imaging of Acetylcholine Using MRIUF1NS107713 · NINDS · NORTHEASTERN UNIVERSITY · PI CLARK, HEATHER A, FLASK, CHRISTOPHER A · 2018 to 2018
$1.6M
NCI NIH HHS R01 CA269354NIGMS NIH HHS T32 GM007250NIGMS NIH HHS T32 GM152319NINDS NIH HHS UF1 NS107713
6 · The paper itself

Abstract

Conventional diagnostic images from Magnetic Resonance Imaging (MRI) are typically qualitative and require subjective interpretation. Alternatively, quantitative MRI (qMRI) methods have become more prevalent in recent years with multiple clinical and preclinical imaging applications. Quantitative MRI studies on preclinical MRI scanners are being used to objectively assess tissues and pathologies in animal models and to evaluate new molecular MRI contrast agents. Low-field preclinical MRI scanners (≤3.0T) are particularly important in terms of evaluating these new MRI contrast agents at human MRI field strengths. Unfortunately, these low-field preclinical qMRI methods are challenged by long acquisition times, intrinsically low MRI signal levels, and susceptibility to motion artifacts. In this study, we present a new rapid qMRI method for a preclinical 3.0T MRI scanner that combines a Spiral Acquisition with a Matching-Based Algorithm (SAMBA) to rapidly and quantitatively evaluate MRI contrast agents. In this initial development, we compared SAMBA with gold-standard Spin Echo MRI methods using Least Squares Fitting (SELSF) in vitro phantoms and demonstrated shorter scan times without compromising measurement accuracy or repeatability. These initial results will pave the way for future in vivo qMRI studies using state-of-the-art chemical probes.

Indexed as

low-field preclinical MRIQuantitative MRISpiral Acquisition Matching-Based Algorithm (SAMBA)

Identifiers

PMID39324129
PMCPMC11423800

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.