Evidence map›Paper›PMID 39323238›Full record

ArticleMagnetic resonance in medicine2025

Reduced physiology-induced temporal instability achieved with variable-flip-angle fast low-angle excitation echo-planar technique with multishot echo planar time-resolved imaging.

Zhangxuan Hu, Avery J L Berman, Zijing Dong, William A Grissom, Timothy G Reese, Lawrence L Wald, Fuyixue Wang, Jonathan R Polimeni

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhangxuan HuAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0002-6534-4299
Avery J L BermanAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-7631-1049
Zijing DongAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-9334-0968
William A GrissomDepartment of Biomedical Engineering, School of Medicine, Case School of Engineering, Cleveland, Ohio, USA.
Timothy G ReeseAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Fuyixue WangAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-8975-2775
Jonathan R PolimeniAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.

Funding

Viral Tool Development Core: Visualization and manipulation of brain fluid dynamics by recombinant viral vectorsU19NS128613 · NINDS · UNIVERSITY OF ROCHESTER · PI Patrick James Drew, Hajime Hirase · 2022 to 2026
$13.6M
Project 4U19NS123717 · NINDS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI ROSEN, BRUCE R · 2021 to 2025
$13.4M
Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Aapo Nummenmaa · 2020 to 2026
$10.9M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
Improving Human fMRI through Modeling and Imaging Microvascular Dynamics: Administrative SupplementR01MH111419 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO · 2016 to 2020
$4.9M
Neuroimaging the impact of respiration and respiratory-gated neuromodulation on human glymphatic physiologyR01AT011429 · NCCIH · MASSACHUSETTS GENERAL HOSPITAL · PI Laura Diane Lewis · 2021 to 2026
$3.7M
Advancing fMRI Acquisition through Dissemination of EPTI- An Efficient Distortion-Free Multi-Contrast Imaging TechnologyU24NS129893 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI Fuyixue Wang · 2023 to 2026
$2.6M
System Upgrade for Siemens 7T Human MRI SystemS10OD023637 · OD · MASSACHUSETTS GENERAL HOSPITAL · PI WALD, LAWRENCE L · 2017 to 2017
$2.0M
CRCNS: Waste-clearance flows in the brain measured using physics-informed neural networkR01AT012312 · NCCIH · UNIVERSITY OF ROCHESTER · PI Douglas H Kelley · 2022 to 2026
$1.6M
An acquisition and reconstruction framework to enable mesoscale human fMRI on clinical 3 Tesla scannersR01EB033206 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2022 to 2022
$853k
Imaging brain-wide subarachnoid and perivascular cerebrospinal fluid flow in aging and Alzheimer's diseaseR00AG083056 · NIA · MASSACHUSETTS GENERAL HOSPITAL · PI Zijing Dong · 2025 to 2026
$493k
Imaging brain-wide subarachnoid and perivascular cerebrospinal fluid flow in aging and Alzheimer's diseaseK99AG083056 · NIA · MASSACHUSETTS GENERAL HOSPITAL · PI DONG, ZIJING · 2023 to 2024
$268k
NCCIH NIH HHS R01 AT011429NCCIH NIH HHS R01-AT011429NCCIH NIH HHS R01 AT012312NIA NIH HHS K99 AG083056NIA NIH HHS K99-AG083056NIA NIH HHS R00 AG083056NIBIB NIH HHS P41 EB030006NIBIB NIH HHS P41-EB030006NIBIB NIH HHS R01 EB019437NIBIB NIH HHS R01-EB019437NIBIB NIH HHS R01 EB033206NIBIB NIH HHS R01-EB033206NIH HHS S10 OD023637NIMH NIH HHS R01 MH111419NIMH NIH HHS R01-MH111419NINDS NIH HHS U19 NS123717NINDS NIH HHS U19-NS123717NINDS NIH HHS U19 NS128613NINDS NIH HHS U19-NS128613NINDS NIH HHS U24 NS129893NINDS NIH HHS U24-NS129893ORIP NIH HHS S10-OD023637
6 · The paper itself

Abstract

purposeEcho planar time-resolved imaging (EPTI) is a new imaging approach that addresses the limitations of EPI by providing high-resolution, distortion- and T THEORY AND

methodsIn conventional multishot EPTI, the time intervals between the shots comprising each slice can introduce intershot phase variations. Here, the fast low-angle excitation echo-planar technique (FLEET), in which all shots of each slice are acquired consecutively with minimal time delays, was combined with a variable flip angle (VFA) technique to improve intershot consistency and maximize signal. A recursive Shinnar-Le Roux RF pulse design algorithm was used to generate pulses for different shots to produce consistent slice profiles and signal intensities across shots. Blipped controlled aliasing in parallel imaging simultaneous multislice was also combined with the proposed VFA-FLEET EPTI to improve temporal resolution and increase spatial coverage.

resultsThe temporal stability of VFA-FLEET EPTI was compared with conventional EPTI at 7 T. The results demonstrated that VFA-FLEET can provide spatial-specific increase of temporal stability. We performed high-resolution task-fMRI experiments at 7 T using VFA-FLEET EPTI, and reliable BOLD responses to a visual stimulus were detected.

conclusionThe intershot phase variations induced by physiological processes in multishot EPTI can manifest as specific spatial patterns of physiological noise enhancement and lead to reduced temporal stability. The VFA-FLEET technique can substantially reduce these physiology-induced instabilities in multishot EPTI acquisitions. The proposed method provides sufficient stability and sensitivity for high-resolution fMRI studies.

Indexed as

AlgorithmsBrainEcho-Planar ImagingImage Processing, Computer-AssistedBrain MappingHumansMagnetic Resonance ImagingPhantoms, ImagingReproducibility of Results7T MRIBOLDfMRIhigh spatial resolution fMRISMStemporal SNR

Identifiers

PMID39323238
PMCPMC11661687

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.