Evidence map›Paper›PMID 39320497›Full record

ArticleInternational orthopaedics2024

High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up.

Philipp Schippers, Felix Wunderlich, Yama Afghanyar, Victoria Buschmann, Thomas Klonschinski, Philipp Drees, Lukas Eckhard

Abstract read
In one paragraph

Article in International orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. [Expert consensus on clinical pathway for high-conformity total knee arthroplasty through a minimally invasive surgical approach].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Philipp SchippersDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany. philipp.schippers@unimedizin-mainz.de.ORCID 0000-0002-0005-299X
Felix WunderlichDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Yama AfghanyarDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Victoria BuschmannDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Thomas KlonschinskiDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Philipp DreesDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Lukas EckhardDepartment of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDespite numerous studies demonstrating promising short-term outcomes of Total Knee Arthroplasty (TKA) with Customized Individually Made (CIM) implants, there is a significant lack of data on their mid-term effectiveness. Given the increasing number of TKAs performed annually, the rising demand for CIM implants, and the associated burden of revision surgeries, understanding the mid-term performance of CIM implants is crucial. Therefore, this study aims to report on the mid-term (minimum 5 years) outcomes of TKA using a CIM implant.

methodsThis retrospective cohort study included a consecutive series of 116 patients who received the ConforMIS

resultsThe mean follow-up duration was 5.9 ± 0.8 years (range 5-7.4 years). 90% of patients stated they would undergo the same operation again, and 93% were either satisfied or very satisfied. The mean VAS for pain at rest was 2 ± 1.5 (range 0-6) and during exercise was 3 ± 2 (range 0-8). 58 patients (53%) managed to lose weight. The mean OKS was 41 ± 9 points (range 15-48), and the mean FJS-knee was 67 ± 23 points (range 4-100). No severe complications occurred.

conclusionCIM TKA using the ConforMIS

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneePatient SatisfactionAgedAged, 80 and overFemaleFollow-Up StudiesHumansKnee JointMaleMiddle AgedPain MeasurementProsthesis DesignRetrospective StudiesSurveys and QuestionnairesConformisCustomized, individually madeTotal knee arthroplasty

Identifiers

PMID39320497
PMCPMC11564282

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked