Evidence map›Paper›PMID 39320328›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

An Injection Molded SlipChip with Self-Sampling for Integrated Point-of-Care Testing of Human Papilloma Virus.

Jiajie Zhang, Zhangli Dong, Lei Xu, Xu Han, Zheyi Sheng, Weiyu Chen, Jiayi Zheng, Dongmei Lai, Feng Shen

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. A Field-Deployable RotEx-LAMP-LFA Platform for Molecular Triage of HPV-Driven Oncogenesis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  3. Article
  4. Human papillomavirus infection and screening strategies.World journal of clinical oncology · 2025
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jiajie ZhangSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
Zhangli DongThe International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200030, China.
Lei XuSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
Xu HanThe International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200030, China.
Zheyi ShengSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
Weiyu ChenSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
Jiayi ZhengSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
Dongmei LaiThe International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200030, China.
Feng ShenSchool of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.ORCID 0000-0002-4709-330X

Funding

Interdisciplinary Program of Shanghai Jiao Tong University YG2022QN012Interdisciplinary Program of Shanghai Jiao Tong University YG2022QN049Interdisciplinary Program of Shanghai Jiao Tong University YG2022ZD028National Natural Science Foundation of China 32171463Natural Science Foundation of Shanghai 23ZR1432900
6 · The paper itself

Abstract

High-risk human papillomavirus (HPV) screening is crucial for cervical cancer prevention. However, laboratory-based nucleic acid amplification tests (NAATs) require costly equipment, designated lab space, and skilled personnel. Additionally, cervical swabs collected by healthcare professionals can be inconvenient, uncomfortable, and reduce privacy, limiting broader application and patient compliance. A SlipChip-based Integrated Point-of-Care (SIPOC) system featuring an injection-molded SlipChip is presented with preloaded reagents for nucleic acid extraction and a portable four-channel real-time quantitative PCR instrument for detection. This system incorporates a self-sampling method that allows participants to collect their own vaginal swabs, with the β-Globin gene as a control. After testing 130 participants for HPV-16 and HPV-18, 97.7% of the self-collected samples are valid. Among valid samples, 25 tested positive for HPV-16 and 9 for HPV-18. Compared to Roche's standard HPV PCR test, the SIPOC system shows 100% positive predictive value (PPV) for both HPV-16 and HPV-18 and negative predictive values (NPVs) of 99.0% and 99.1%, respectively. This system is promising for HPV screening in resource-limited settings and adaptable for other point-of-care NAAT applications, including home testing.

Indexed as

Papillomavirus InfectionsPoint-of-Care TestingAdultFemaleHuman papillomavirus 16Human papillomavirus 18Human Papillomavirus VirusesHumansMiddle AgedPapillomaviridaePoint-of-Care SystemsReal-Time Polymerase Chain ReactionSensitivity and SpecificitySpecimen HandlingUterine Cervical NeoplasmsHPV screeninglab on a Chipmicrofluidicspoint of careself‐samplingSlipChip

Identifiers

PMID39320328
PMCPMC11578293

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.