Evidence map›Paper›PMID 39319892›Full record

ArticleRevista latino-americana de enfermagem2024

Complications in the use of peripherally inserted central catheter associated with peripheral intravenous therapy: retrospective cohort.

Elizângela Santana Dos Santos, Elaine Barros Ferreira, Fernanda Titareli Merizio Martins Braga, Amanda Salles Margatho, Paulo Sousa, Renata Cristina de Campos Pereira Silveira

Abstract read
In one paragraph

Article in Revista latino-americana de enfermagem, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elizângela Santana Dos SantosUniversidade de São Paulo, Escola de Enfermagem de Ribeirão Preto, Centro Colaborador de la OPS/OMS para el Desarrollo de la Investigación en Enfermería, Ribeirão Preto, SP, Brazil.ORCID 0000-0003-4602-1926
Elaine Barros FerreiraUniversidade de Brasília, Faculdade de Ciências da Saúde, Brasília, DF, Brazil.ORCID 0000-0003-0428-834X
Fernanda Titareli Merizio Martins BragaUniversidade de São Paulo, Escola de Enfermagem de Ribeirão Preto, Centro Colaborador de la OPS/OMS para el Desarrollo de la Investigación en Enfermería, Ribeirão Preto, SP, Brazil.ORCID 0000-0001-8089-788X
Amanda Salles MargathoUniversidade de São Paulo, Escola de Enfermagem de Ribeirão Preto, Centro Colaborador de la OPS/OMS para el Desarrollo de la Investigación en Enfermería, Ribeirão Preto, SP, Brazil.ORCID 0000-0002-1006-9357
Paulo SousaUniversidade Nova de Lisboa, Escola Nacional de Saúde Pública, Lisboa, Estremadura, Portugal.ORCID 0000-0001-9502-6075
Renata Cristina de Campos Pereira SilveiraUniversidade de São Paulo, Escola de Enfermagem de Ribeirão Preto, Centro Colaborador de la OPS/OMS para el Desarrollo de la Investigación en Enfermería, Ribeirão Preto, SP, Brazil.ORCID 0000-0002-2883-3640

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveto analyze the occurrence of difficulty in the peripheral insertion of the central catheter and the presence of complications in the use of this device in hospitalized adults who received peripheral intravenous therapy through a short peripheral intravenous catheter and to identify whether there is an association between peripheral intravenous therapy and the presence of complications in the use of the peripherally inserted central catheter.

methodretrospective cohort, with patients aged 18 years or over, in a tertiary teaching hospital, with a peripherally inserted central catheter, who had at least one previous short peripheral intravenous catheter. Data were analyzed using descriptive statistics and Poisson regression.

resultsthe sample consisted of 76 patients. There was an association between difficulty in the insertion procedure and number of punctures (p<0.01) and insertion in the external jugular vein compared to the upper limbs (p<0.01). The insertion site was also associated with the removal of the peripherally inserted central catheter due to complications in the robust analysis of variance (p=0.02). No associations were identified between: difficulty inserting the device and time on peripheral intravenous therapy (crude model p=0.23; adjusted model p=0.21); difficulty in insertion with administration of irritating and vesicant medication (crude model p=0.69; adjusted model p=0.53); complication in the use of peripherally inserted central catheter and time of peripheral intravenous therapy (crude and adjusted models p=0.08); and secondary migration of the catheter tip with the device insertion site (p=0.24).

conclusionit was possible to identify secondary migration as one of the main complications, resulting in premature removal of the device. Furthermore, the greater the number of puncture attempts to insert the PICC, the greater the difficulty in inserting it. Insertion into the external jugular vein was recurrent, with a higher risk of removal due to complications in relation to the upper limbs.

Indexed as

Catheterization, PeripheralAdministration, IntravenousAdultAgedCatheterization, Central VenousCohort StudiesFemaleHumansMaleMiddle AgedRetrospective Studies

Identifiers

PMID39319892
PMCPMC11421515

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.