ArticleRespirology case reports2024
Successful treatment of tracheal stenosis due to a broken uncovered metallic stent placed over 20 years ago in a patient with recurrent polychondritis using argon plasma coagulation and airway ballooning.
Article in Respirology case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Successful Placement of a Silicone Y-Stent Using the Pullback Technique Through a Self-Expandable Metallic Stent in a Case of Tuberculous Airway Stenosis.Respirology case reports · 2025Article
- The role of bronchoscopy in benign airway stenosis: literature review of a central procedure guiding multidisciplinary care and therapeutic approach for improving patient outcomes.Journal of visualized surgery · 2025Review
- Successful treatment of tracheal stenosis due to a broken uncovered metallic stent placed over 20 years ago in a patient with recurrent polychondritis using argon plasma coagulation and airway ballooning.Respirology case reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A woman in her mid-60s with recurrent polychondritis was admitted to our hospital due to airway stenosis secondary to an uncovered metallic stent. She underwent a bronchoscopic intervention under general anaesthesia. During the procedure, the stent fracture was cauterized using Argon Plasma Coagulation (APC) cauterisation, performed with argon flow at 1 L/min and power set at 70 W. APC cauterisation caused the stent wire to flex circularly, gradually improving the stenosis. Tracheal dilatation was then performed using an airway balloon. Following the ballooning, a thin bronchoscope was easily passed through the lower trachea, and the left and right main bronchi were observed; therefore, the procedure was completed without any complications. APC coagulation and airway ballooning are viable choices for the temporary treatment of airway stenosis due to broken metallic stents.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.