Evidence map›Paper›PMID 39319333›Full record

ArticleRespirology case reports2024

Successful treatment of tracheal stenosis due to a broken uncovered metallic stent placed over 20 years ago in a patient with recurrent polychondritis using argon plasma coagulation and airway ballooning.

Yuki Takigawa, Ken Sato, Kenichiro Kudo, Takeru Ichikawa, Yuto Sasano, Shoichiro Matsumoto, Tomoyoshi Inoue, Miho Fujiwara, Suzuka Matsuoka, Hiromi Watanabe and 3 more

Abstract readCase Reports
In one paragraph

Article in Respirology case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Yuki TakigawaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.ORCID https://orcid.org/0000-0003-0613-0423
Ken SatoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Kenichiro KudoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Takeru IchikawaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Yuto SasanoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Shoichiro MatsumotoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Tomoyoshi InoueDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Miho FujiwaraDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.ORCID https://orcid.org/0009-0009-3790-4373
Suzuka MatsuokaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Hiromi WatanabeDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Akiko SatoDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Keiichi FujiwaraDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.
Takuo ShibayamaDepartment of Respiratory Medicine NHO Okayama Medical Center Okayama Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A woman in her mid-60s with recurrent polychondritis was admitted to our hospital due to airway stenosis secondary to an uncovered metallic stent. She underwent a bronchoscopic intervention under general anaesthesia. During the procedure, the stent fracture was cauterized using Argon Plasma Coagulation (APC) cauterisation, performed with argon flow at 1 L/min and power set at 70 W. APC cauterisation caused the stent wire to flex circularly, gradually improving the stenosis. Tracheal dilatation was then performed using an airway balloon. Following the ballooning, a thin bronchoscope was easily passed through the lower trachea, and the left and right main bronchi were observed; therefore, the procedure was completed without any complications. APC coagulation and airway ballooning are viable choices for the temporary treatment of airway stenosis due to broken metallic stents.

Indexed as

airway stenosisargon plasma coagulationrecurrent polychondritisUltraflex stent

Identifiers

PMID39319333
PMCPMC11421887

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked