ArticleCureus2024
Management of Persistent Left Superior Vena Cava: Overcoming Lead and Vascular Complications With Transcatheter Pacing System Implantation.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Isolated persistent left superior vena cava (PLSVC) is a rare congenital anomaly typically found incidentally due to its asymptomatic nature. However, it can present technical challenges for device implanters. We report a case involving a patient with PLSVC, for whom the implantation of a transcatheter pacing system proved to be the most effective long-term solution. Although this venous anomaly initially provided a safe pacing route, it eventually led to early complications. The patient, a 78-year-old Puerto Rican man with hypertension, diabetes mellitus, and complete atrioventricular block, experienced multiple complications with pacing devices. After a failed left-sided pacemaker implant, a right-sided single-chamber ventricular device was placed, but it led to right ventricular lead fractures and was eventually abandoned. A new pacing system implanted in the left chest lasted only a year. Venography revealed a patent PLSVC with a previously implanted device now obstructed by an occluded left brachiocephalic vein. After laser-assisted extraction, a dual-chamber device was successfully implanted through the PLSVC. Despite unremarkable physical and lab results, the patient later showed syncope and high lead impedances with fractures in both leads and total PLSVC occlusion. A transcatheter pacing system was chosen to address the complex anatomical issues and abandoned hardware. Atrial synchronized pacing was confirmed the morning after implantation, and the patient was safely discharged. Ensuring a stable ventricular rhythm is crucial for patients with complete heart block. When hemodynamic stability is compromised by recurrent lead fractures and rare anatomical variants, implanters must consider alternative solutions. In this case, a transcatheter system was selected to avoid further lead and pocket-related complications and mitigate the risks of additional laser-assisted extractions. At the end of the device's lifespan, a new device can be implanted without significant anatomical issues, and the epicardial route remains a viable option if necessary.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.