Evidence map›Paper›PMID 39318862›Full record

ArticleArchives of academic emergency medicine2025

Comparison of Video Laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) for Endotracheal Intubation in a Manikin with Restricted Neck Motion.

Welawat Tienpratarn, Methapat Boonyingsatit, Chaiyaporn Yuksen, Sittichok Leela-Amornsin, Parunchaya Jamkrajang, Thammanunt Chrunarm, Sumate Rienrakwong

Abstract read
In one paragraph

Article in Archives of academic emergency medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Advancing emergency airway management: Video laryngoscopeWorld journal of critical care medicine · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Welawat TienpratarnDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Thailand.
Methapat BoonyingsatitDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Thailand.
Chaiyaporn YuksenDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Thailand.
Sittichok Leela-AmornsinChakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Thailand.
Parunchaya JamkrajangCollege of Sports Science and Technology, Mahidol University, Thailand.
Thammanunt ChrunarmCollege of Sports Science and Technology, Mahidol University, Thailand.
Sumate RienrakwongCollege of Sports Science and Technology, Mahidol University, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Intubating patients undergoing manual in-line stabilization (MILS) can make airway management more challenging. This study aimed to compare the outcomes of intubation with video-laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) in manikin with restricted neck motion using MILS. Methods: In this comparative study, emergency medicine residents and paramedics were randomly allocated to two crossover sets. Then the intubation outcomes (success rate, time to successful intubation, and cervical spine movement) were compared between intubation with VL and I-LMA in a manikin model with restricted cervical spine mobility, achieved through MILS. Results: 64 participants with a mean age of 28.86 ± 4.03 (range: 24-47) years and a mean duration of intubation experience of 3.63 ± 1.35 years were studied (43.75% male, 81.3% emergency medicine resident). The intubation success rate was 62 out of 64 (96.88%) in the VL method and 52 out of 64 (81.25%) in the I-LMA method (p = 0.008). The mean time to successful intubation was 33.03±16.94 seconds in the VL method and 55.03±17.34 seconds in the I-LMA method (p < 0.001). The mean cervical range of motion (CROM) in flexion-extension was 4.38±1.82 degrees in the VL method and 4.13±3.20 degrees in the I-LMA method (p = 0.158). The mean CROM in rotation was 4.27±2.62 degrees in the VL method and 4.65±2.47 degrees in the I-LMA method (p= 0.258) and the mean CROM in lateral bending was 5.35±4.45 degrees in the VL method and 7.71±6.14 degrees in the I-LMA method (p = 0.010). Conclusion: In a manikin model with restricted cervical spine mobility, the utilization of VL significantly improved intubation success rates, reduced time to successful intubation, and limited CROM.

Indexed as

Video laryngoscope; intubating LMA; Manual in-line stabilization; Success intubation

Identifiers

PMID39318862
PMCPMC11417637

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.