Evidence map›Paper›PMID 39318641›Full record

ArticleHardwareX2024

CARETestLung: A mechanical test lung with Configurable airway Resistance, lung Elastance, and breathing efforts.

Wei Yang Tay, Christopher Yew Shuen Ang, Yeong Shiong Chiew, J Geoffrey Chase

Abstract read
In one paragraph

Article in HardwareX, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wei Yang TayMonash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia.
Christopher Yew Shuen AngMonash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia.
Yeong Shiong ChiewMonash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia.
J Geoffrey ChaseDepartment of Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A mechanical test lung is a crucial tool in accurately simulating patient-specific physiological responses of patients undergoing mechanical ventilation (MV), which, in turn, offer clinicians insight into lung mechanics during MV. In particular, it can be used to facilitate better methods to identify optimal ventilator settings, modes for individual patients by providing a platform to experiment with different MV settings. This addresses the challenge of optimising MV settings caused by variability in pathological conditions and the progression of respiratory disease over time within patients. However, the accessibility and cost of versatile test lungs limit widespread adoption in clinical settings, underscoring the need for affordable alternatives. This paper presents detailed instructions for the design and construction of a replicable, cost-effective mechanical test lung. The design features 3 subsystems: 1) the lung compartment; 2) the airway; and 3) a spontaneous breathing system. A detailed tests series shows its ability to replicate clinically realistic lung elastance values ranging from 25 to 85 cmH

Indexed as

Mechanical test lungMechanical ventilationSpontaneous breathing

Identifiers

PMID39318641
PMCPMC11419886

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.