ArticleDie Anaesthesiologie2024
[Transport of severely injured trauma patients in an ambulance with and without a rigid neck orthosis: comparative biomechanical measurements].
Article in Die Anaesthesiologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Effectiveness and safety of techniques for cervical spine immobilization in mountain rescue.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe actual significance of prehospital immobilization of the cervical spine in severely injured trauma patients remains unclear. In view of possible negative implications, such as an increase in intracranial pressure due to the application of a rigid cervical spine orthosis, the long-term use must be critically questioned. Further studies are required to justify the long-term use of a rigid cervical spine orthosis in the prehospital setting.
objectiveComparative measurements of the mobility of the cervical spine during immobilization using a vacuum mattress with or without the additional application of a rigid cervical spine orthosis after positioning on the stretcher were carried out. MATERIAL AND
methodsBiomechanical measurements of the movement of the cervical spine were carried out by attaching inertial measurement units to a test person during the loading and unloading process in a modern ambulance and during the journey along a predefined parkour. The test person on whom the measurements were carried out was immobilized on a vacuum mattress with the option of lateral fixation of the head and chin and forehead strap on an electrohydraulic stretcher. The complete standard monitoring was set up to simulate as realistic a transport of a severely injured patient as possible. A total of 30 test runs were realized. In one half of the tests, the cervical spine was additionally immobilized using a rigid orthosis and in the other half a cervical spine orthosis was not used. For each of the 30 tests, the angles, axial rotation, lateral bending and flexion/extension as well as the first and second derivatives were considered for loading, transport and unloading and the parameters mean deviation from the zero position, size of the swept angle range and maximum were calculated for each test run.
resultsStatistically significant differences were only found for some biomechanical parameters in the sagittal plane (flexion and extension). No significant differences were found for the measured parameters in the other directions of movement (axial rotation, lateral flexion). In general, only very small angular deflections were measured both in the tests with the cervical spine orthosis and without the cervical spine orthosis (on average in the range of 1-2° for axial rotation and flexion/extension and up to 3° for lateral flexion).
conclusionIf immobilization is carried out correctly using a vacuum mattress with the option of lateral stabilization of the head and chin and a forehead strap on an electrohydraulic stretcher with a loading system, there are no relevant advantages with respect to the restriction of movement of the cervical spine by the additional use of a rigid cervical spine orthosis for the loading and unloading process or during the transport in a modern ambulance. It could therefore be advantageous to remove the rigid cervical spine orthosis initially applied for the rescue of the patient at the scene after the patient has been positioned on the vacuum mattress and stretcher to avoid potential negative effects of the rigid cervical spine orthosis for the period of transportation to the hospital.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.