Evidence map›Paper›PMID 39313843›Full record

ArticleOrthopaedic surgery2024

Innovative 3D Navigation Module for Precise Unilateral Pedicle Screw Combined with Contralateral Translaminar Facet Screw Placement in Lumbar Spine Surgery.

Xu Chen, Hanhao Dai, Jun Luo, Huaizhi Zhang, Chao Song, Zhibo Deng, Yanyan Zhang, Xing Li, Jianhui Dai, Jie Xu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Xu ChenDepartment of Orthopedics, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Hanhao DaiDepartment of Orthopedics, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Jun LuoDepartment of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, China.
Huaizhi ZhangDepartment of Minimally Invasive Spinal Surgery, The Affiliated Hospital of Putian University, Putian, China.
Chao SongDepartment of Orthopedics, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Zhibo DengDepartment of Orthopedics, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Yanyan ZhangDepartment of Minimally Invasive Spinal Surgery, The Affiliated Hospital of Putian University, Putian, China.
Xing LiDepartment of Minimally Invasive Spinal Surgery, The Affiliated Hospital of Putian University, Putian, China.
Jianhui DaiDepartment of Minimally Invasive Spinal Surgery, The Affiliated Hospital of Putian University, Putian, China.
Jie XuDepartment of Orthopedics, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.ORCID https://orcid.org/0009-0002-4940-4439

Funding

Flint Fund project 2020HSJJ20Major Scientific Research Project of Fujian Province 2021ZD01003Medical Innovation Project of Fujian Provincial Health Department 2020QNA009Medical Innovation Project of Fujian Provincial Health Department 2021CXA007Natural Science Foundation of Fujian Province 2020J011101Natural Science Foundation of Fujian Province 2020J05270Natural Science Foundation of Fujian Province 2021J01376Natural Science Foundation of Fujian Province 2022J011016Natural Science Foundation of Fujian Province 2022J011440Natural Science Foundation of Fujian Province 2023J011200
6 · The paper itself

Abstract

objectiveThe incidence of degenerative diseases of the lumbar spine has increased in recent years. Unilateral pedicle screw combined with contralateral translaminar facet screw fixation offers the advantages of less trauma, better stability, and fewer complications. However, the surgical difficulty and suboptimal pinning accuracy of translaminar facet screw placement in clinical practice limit its use. Therefore, in this study, we designed a novel suspended 3D-printed navigation module to facilitate fast and accurate intraoperative screw placement. The aim of this study is to investigate the digital design, precise implementation, and evaluation methods for placing unilateral pedicle screws in the lumbar spine combined with translaminar facet screw placement using a new suspended 3D navigation module.

methodsThis retrospective study included 46 patients with single-level lumbar lesions who underwent spine surgery at the Affiliated Hospital of Putian University between June 2022 and December 2023. The suspended navigation module was designed digitally. Preoperative screw placement was simulated using 3D printed models, followed by an intraoperative accurate screw placement facilitated by the navigation module and a postoperative evaluation of the accuracy of screw placement. The absolute difference in three-dimensional coordinates of the inlet and outlet points of the preoperative design and the postoperative screw-nail channel served as the precision index.

resultsIn a study involving 46 patients, surgery was successful with 92 pedicle screws and 46 translaminar facet screws placed without any penetration of the cortex. The difference in coordinates before and after screw insertion was minimal, with entry points varying between 1.21 to 1.36 mm and exit points between 1.97 to 2.46 mm. When screw accuracy met certain thresholds, there was no significant difference between preoperative design and postoperative coordinates, indicating precise replication of the surgical plan.

conclusionThe new suspended 3D navigation module enables the precise placement of unilateral pedicle screws in the lumbar spine combined with translaminar pedicle screws for precise surgery.

Indexed as

Lumbar VertebraePedicle ScrewsPrinting, Three-DimensionalSurgery, Computer-AssistedAdultAgedFemaleHumansImaging, Three-DimensionalMaleMiddle AgedRetrospective StudiesSpinal Fusion3D PrintingAccuracyDigital DesignPedicle Screw PlacementTranslaminar Facet Screw Placement

Identifiers

PMID39313843
PMCPMC11608785

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.