ArticleMagnetic resonance in medicine2025
In vivo cardiac diffusion tensor imaging on an MR system featuring ultrahigh performance gradients with 200 mT/m maximum gradient strength.
Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Comparative Performance Analysis of an Open Source Motion-Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths-A Pilot Study.Magnetic resonance in medicine · 2026Article
- Technical Feasibility of IVIM for Prostate Cancer Imaging Using High-Amplitude Whole-Body Gradient System With Spiral Readout and Velocity-Compensated Diffusion Encoding.NMR in biomedicine · 2026Article
- Evaluation of Third-Order Motion-Compensated Cardiac Diffusion Tensor Imaging Across Cardiac Phases Using an Ultra-High-Performance Clinical Scanner.Magnetic resonance in medicine · 2026Article
- Optimized Reduced Field of View and Fat Suppression Methods for Interleaved Multislice In Vivo Cardiac Diffusion Tensor Imaging.Magnetic resonance in medicine · 2026Article
- Electromagnetic and Electrophysiological Modeling of Cardiac Stimulation Thresholds in 13 MRI Gradient Systems and 56 Body Models.Magnetic resonance in medicine · 2026Article
- Human Brain High-Resolution Diffusion MRI With Optimized, Slice-By-Slice, Zeroth and First OrderMagnetic resonance in medicine · 2026Article
- Strong-Gradient Diffusion-Weighted Imaging of Prostate Cancer Using an Inside-Out Nonlinear Gradient Coil.Magnetic resonance in medicine · 2026Article
- Free-Breathing Multi-Slice Co-Registered Cardiac T1, T2, and ADC Mapping With Spin-Echo Echo Planar Imaging.Magnetic resonance in medicine · 2026Article
- The Effect of Voxel Volume and Voxel Shape on Cardiac Diffusion Tensor Imaging Metrics.Magnetic resonance in medicine · 2026Article
- Cartesian MaxGIRF: Model-based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects.Magnetic resonance in medicine · 2026Article
- Diffusion tractography outside the brain: the road less travelled.Brain structure & function · 2026Review
- In vivo cardiac diffusion tensor imaging on an MR system featuring ultrahigh performance gradients with 200 mT/m maximum gradient strength.Magnetic resonance in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
purposeOur aim is to assess the potential of an MR system with ultrahigh performance gradients (200 mT/m maximum gradient strength) to address two interrelated challenges in cardiac DTI: low SNR and sensitivity to bulk motion.
methodsImaging was performed in 20 healthy volunteers, two patients, and one swine post-myocardial infarction. The impact of maximum gradient strength was assessed with spin echo cardiac DTI featuring second-order motion compensation and varying maximum system gradient strengths (40, 80, 200 mT/m). Motion compensation requirements at 200 mT/m were assessed with sequences featuring zeroth-, first-, and second-order motion compensation. SNR, mean diffusivity, fractional anisotropy, helix angle transmurality, and secondary eigenvector angle in the left ventricle were compared.
resultsIncreasing maximum system gradient strength from 40 and 80 mT/m to 200 mT/m increased SNR of b = 500 s/mm
conclusionUltrahigh performance gradients (200 mT/m) enable high SNR DWIs of the heart and resultant improvements in diffusion tensor metrics. Despite reduced diffusion-encoding duration, second-order motion compensation is required to overcome sensitivity to cardiac motion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials