Evidence map›Paper›PMID 39313529›Full record

ArticleCommunications engineering2024

Acoustically semitransparent nanofibrous meshes appraised by high signal-to-noise-ratio MEMS microphones.

Hutomo Suryo Wasisto, Sebastian Anzinger, Giovanni Acanfora, Aloysius Farrel, Valentina Sabatini, Elisa Grimoldi, Vasco Marelli, Nikita Ovsiannikov, Konstantin Tkachuk, Giordano Tosolini and 5 more

Abstract read
In one paragraph

Article in Communications engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Hutomo Suryo WasistoInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany. hutomosuryo.wasisto@infineon.com.ORCID http://orcid.org/0000-0002-4522-3625
Sebastian AnzingerInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0000-0002-6272-590X
Giovanni AcanforaInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0009-0005-2202-2328
Aloysius FarrelInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0009-0009-3563-6555
Valentina SabatiniSAATI SPA, Via Milano 14, Appiano Gentile, Como, Italy.ORCID http://orcid.org/0000-0002-6902-4540
Elisa GrimoldiSAATI SPA, Via Milano 14, Appiano Gentile, Como, Italy.ORCID http://orcid.org/0009-0002-4714-0169
Vasco MarelliSAATI SPA, Via Milano 14, Appiano Gentile, Como, Italy.ORCID http://orcid.org/0000-0002-3411-874X
Nikita OvsiannikovInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0009-0008-4788-9288
Konstantin TkachukInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0009-0000-0997-0888
Giordano TosoliniInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.
Carmine LucignanoSAATI SPA, Via Milano 14, Appiano Gentile, Como, Italy.ORCID http://orcid.org/0009-0004-5801-0057
Marco MiettaSAATI SPA, Via Milano 14, Appiano Gentile, Como, Italy.ORCID http://orcid.org/0009-0006-1796-342X
Guangzhao ZhangInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.ORCID http://orcid.org/0009-0005-3971-4224
Marc FueldnerInfineon Technologies AG, Am Campeon 1-15, Neubiberg, Germany.
Erwin PeinerInstitute of Semiconductor Technology (IHT) and Laboratory for Emerging Nanometrology (LENA), Technische Universität Braunschweig, Hans-Sommer-Str. 66, Braunschweig, Germany. e.peiner@tu-braunschweig.de.ORCID http://orcid.org/0000-0001-5801-813X

Funding

Technische Universität Braunschweig (Technische Universität Carolo-Wilhelmina zu Braunschweig) DEAL
6 · The paper itself

Abstract

Microelectromechanical system-based microphones demand high ingress protection levels with regard to their use in harsh environment. Here, we develop environmental protective components comprising polyimide nanofibers combined onto polyether ether ketone fabric meshes and subsequently appraise their impact on the electroacoustic properties of high signal-to-noise-ratio microelectromechanical system-based microphones via industry-standard characterizations and theoretical simulations. Being placed directly on top of the microphone sound port, the nanofiber mesh die-cut parts with an inner diameter of 1.4 mm result in signal-to-noise-ratio and insertion losses of (2.05 ± 0.16) dB(A) and (0.30 ± 0.11) dBFS, respectively, in electroacoustic measurements. Hence, a high signal-to-noise-ratio value of (70.05 ± 0.17) dB(A) can be maintained by the mesh-protected microphone system. Due to their high temperature stability, acoustic performance, environmental robustness, and industry-scale batch production, these nanofibrous meshes reveal high potential to be practically implemented in high-market-volume applications of packaged microelectromechanical system-based microphones.

Identifiers

PMID39313529
PMCPMC11420236

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.