ArticleCureus2024
Development and Validation of a Malay Version Questionnaire to Evaluate Remote Health Monitoring of COVID-19 via Telehealth Applications: Navigating Telehealth Evolution.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Satisfaction towards virtual consultation services and its associated factors among patients in Malaysian public primary care.BMC health services research · 2026Article
- Development of the malay version of the patient satisfaction questionnaire for virtual consultation services (MPSQ-VC): content validity & face validity analysis.BMC health services research · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction The rapid adoption of telehealth services due to the COVID-19 pandemic has highlighted the necessity for effective tools to evaluate patient experiences. This study developed and validated the Telehealth Usability, Acceptability, and Satisfaction Questionnaire (TUASQ) for virtual COVID-19 Assessment Centres (CACs) in Malaysia, aiming to comprehensively measure usability, acceptability, and satisfaction. Methodology The TUASQ was developed in two phases. Initially, the questionnaire development phase included item generation guided by the Technology Acceptance Model (TAM) and the Health Belief Model (HBM), with feedback from a panel of six experts. Items were refined through Content Validity Index (CVI) - Item-Level Content Validity Index (I-CVI) ≥ 0.82, Scale-Level Content Validity Index (S-CVI) ≥ 0.82, and Content Validity Ratio (CVR ≥ 0.78); and Face Validity Index (FVI) by 10 respondents - Item-Level Face Validity Index (I-FVI) ≥ 0.82 and Scale-Level Face Validity Index (S-FVI ≥ 0.82). The psychometric validation phase involved a cross-sectional study of 705 respondents, recruited through convenience sampling from March to July 2024, to perform Exploratory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA), followed by reliability testing using Cronbach's alpha, Composite Reliability (CR), and Average Variance Extracted (AVE). Results Content validation showed that most items' I-CVI exceeded 0.82, indicating significant expert consensus on relevance and clarity. The CVR also surpassed the 0.78 threshold, affirming their essential role. Face validation indices generally exceeded 0.80, confirming the questionnaire's clarity and comprehensiveness from the users' perspective. EFA with 250 participants indicated a high Kaiser-Meyer-Olkin Measure of Sampling Adequacy (KMO) of 0.933 and significant Bartlett's test (χ² (136) = 3752.698, p < 0.001), supporting the factorability of the data and extracting three distinct factors. CFA with 455 participants initially showed a poor fit, prompting model adjustments that subsequently improved the fit indices (Root Mean Square Error of Approximation (RMSEA) = 0.076, Standardized Root Mean Square Residual (SRMR) = 0.045, Goodness of Fit Index (GFI) = 0.94, Tucker-Lewis Index (TLI) = 0.96, Comparative Fit Index (CFI) = 0.97). Reliability testing revealed a high internal consistency with Cronbach's alpha of 0.975. CR for each factor exceeded the 0.70 threshold, and the AVE for each factor was above 0.50, indicating good convergent validity. Conclusion The validated TUASQ is a reliable and effective instrument for assessing the experiences of Malaysian patients using virtual CAC. Demonstrating robust psychometric properties through comprehensive validation processes, the TUASQ accurately measures usability, acceptability, and satisfaction, identifying strengths and areas for improvement in telehealth services. This contributes to enhanced care quality and patient satisfaction in the evolving healthcare landscape.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.