ArticleACS omega2024
Laser-Induced Graphene Strain Sensors for Body Movement Monitoring.
Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Laser-Induced Graphene on Biocompatible PDMS/PEG Composites for Limb Motion Sensing.Sensors (Basel, Switzerland) · 2025Article
- Flexible Stretchable Strain Sensor Based on LIG/PDMS for Real-Time Health Monitoring of Test Pilots.Sensors (Basel, Switzerland) · 2025Article
- Personalized Kirigami Strain Sensors for in vivo Applications.Advanced intelligent systems (Weinheim an der Bergstrasse, Germany) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To enable the development of artificial intelligence of things, the improvement of the strain sensing mechanisms and optimization of the interconnections are needed. Direct laser writing to obtain laser-induced graphene (LIG) is being studied as a promising technique for producing wearable, lightweight, highly sensitive, and reliable strain sensors. These devices show a higher degree of flexibility and stretchability when transferred to an elastomeric substrate. In this article, we manufactured polydimethylsiloxane (PDMS)-encapsulated LIG piezoresistive strain sensors with a quasi-linear behavior and a gauge factor of 111. The produced LIG was morphologically characterized via Raman spectroscopy and scanning electron microscopy before and after the electromechanical characterization and before and after the LIG transfer to PDMS. The results from these analyses revealed that the integrity of the material after the test was not affected and that the LIG volume in contact with the substrate increased after transfer and encapsulation in PDMS, leading to the improvement of the sensor performance. The sensors' capability for measuring bend angles accurately was demonstrated experimentally, making them useable in a wide range of applications for human body movement monitoring as well as for structural health monitoring. Regarding body monitoring, a PDMS-encapsulated LIG sensor for knee bending angle detection was proposed. This device showed unaffected performance of 1500 cycles under 8% uniaxial deformation and with response times in the range of 1-2 s.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.