Evidence map›Paper›PMID 39310177›Full record

ArticleACS omega2024

Quantification of Lanthanides on a PMMA Microfluidic Device with Three Optical Pathlengths Using PCR of UV-Visible, NIR, and Raman Spectroscopy.

Hope E Lackey, Alyssa F Espley, Savannah M Potter, Fabrice Lamadie, Manuel Miguirditchian, Gilbert L Nelson, Samuel A Bryan, Amanda M Lines

Abstract read
In one paragraph

Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hope E LackeyPacific Northwest National Laboratory, Richland, Washington 99352, United States.
Alyssa F EspleyPacific Northwest National Laboratory, Richland, Washington 99352, United States.
Savannah M PotterPacific Northwest National Laboratory, Richland, Washington 99352, United States.
Fabrice LamadieCEA, DES, ISEC, DMRC, Univ Montpellier, Marcoule, 30207 Bagnols-sur-Cèze, France.ORCID https://orcid.org/0000-0002-1449-5986
Manuel MiguirditchianCEA, DES, ISEC, DMRC, Univ Montpellier, Marcoule, 30207 Bagnols-sur-Cèze, France.
Gilbert L NelsonThe College of Idaho, Caldwell, Idaho 83605, United States.
Samuel A BryanPacific Northwest National Laboratory, Richland, Washington 99352, United States.ORCID https://orcid.org/0000-0002-8826-0880
Amanda M LinesPacific Northwest National Laboratory, Richland, Washington 99352, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microfluidic devices (MFDs) offer customizable, low-cost, and low-waste platforms for performing chemical analyses. Optical spectroscopy techniques provide nondestructive monitoring of small sample volumes within microfluidic channels. Optical spectroscopy can probe speciation, oxidation state, and concentration of analytes as well as detect counterions and provide information about matrix composition. Here, ultraviolet-visible (UV-vis) absorbance, near-infrared (NIR) absorbance, and Raman spectroscopy are utilized on a custom poly(methyl methacrylate) (PMMA) MFD for the detection of three lanthanide nitrates in solution. Absorbance spectroscopies are conducted across three pathlengths using three portions of a contiguous channel within the MFD. Univariate and chemometric multivariate modeling, specifically Beer's law regression and principal component regression (PCR), respectively, are utilized to quantify the three lanthanides and the nitrate counterion. Models are composed of spectra from one or multiple pathlengths. Models are also constructed from multiblock spectra composed of UV-vis, NIR, and Raman spectra at one or multiple pathlengths. Root-mean-square errors (RMSE), limit of detection (LOD), and residual predictive deviation (RPD) values are compared for univariate, multivariate, multi-pathlength, and multiblock models. Univariate modeling produces acceptable results for analytes with a simple signal, such as samarium cations, producing an LOD of 5.49 mM. Multivariate and multiblock models produce enhanced quantification for analytes that experience spectral overlap and interfering nonanalyte signals, such as holmium, which had an LOD reduction from 7.21 mM for the univariate model down to 3.96 mM for the multiblock model. Multi-pathlength models are developed that maintain model errors in line with single-pathlength models. Multi-pathlength models have RPDs from 9.18 to 46.4, while incorporating absorbance spectra collected at optical paths of up to 10-fold difference in length.

Identifiers

PMID39310177
PMCPMC11411548

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.