DESIGNING PROGRAMMABLE FERROMAGNETIC SOFT METASTRUCTURES FOR MINIMALLY INVASIVE ENDOVASCULAR THERAPY.

Ran Zhuang, Jiawei Tian, Apostolos Tassiopoulos, Chander Sadasivan, Xianfeng Gu, Shikui Chen

Abstract read
In one paragraph

Article in Proceedings of the ... ASME Design Engineering Technical Conferences. ASME Design Engineering Technical Conferences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ran ZhuangDepartment of Mechanical Engineering, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.
Jiawei TianDepartment of Mechanical Engineering, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.
Apostolos TassiopoulosDepartment of Surgery, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.
Chander SadasivanDepartment of Neurological Surgery, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.
Xianfeng GuDepartment of Computer Science, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.
Shikui ChenDepartment of Mechanical Engineering, State University of New York at Stony Brook, Stony Brook, New York, USA, 11794.

Funding

Magnetically activated structures for minimally invasive endovascular therapyR21EB029733 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI CHEN, SHIKUI, GU, XIANFENG · 2021 to 2021
$627k
NIBIB NIH HHS R21 EB029733
6 · The paper itself

Abstract

Minimally invasive endovascular therapy (MIET) is an innovative technique that utilizes percutaneous access and transcatheter implantation of medical devices to treat vascular diseases. However, conventional devices often face limitations such as incomplete or suboptimal treatment, leading to issues like recanalization in brain aneurysms, endoleaks in aortic aneurysms, and paravalvular leaks in cardiac valves. In this study, we introduce a new metastructure design for MIET employing re-entrant honeycomb structures with negative Poisson's ratio (NPR), which are initially designed through topology optimization and subsequently mapped onto a cylindrical surface. Using ferromagnetic soft materials, we developed structures with adjustable mechanical properties called magnetically activated structures (MAS). These magnetically activated structures can change shape under noninvasive magnetic fields, letting them fit against blood vessel walls to fix leaks or movement issues. The soft ferromagnetic materials allow the stent design to be remotely controlled, changed, and rearranged using external magnetic fields. This offers accurate control over stent placement and positioning inside blood vessels. We performed magneto-mechanical simulations to evaluate the proposed design's performance. Experimental tests were conducted on prototype beams to assess their bending and torsional responses to external magnetic fields. The simulation results were compared with experimental data to determine the accuracy of the magneto-mechanical simulation model for ferromagnetic soft materials. After validating the model, it was used to analyze the deformation behavior of the plane matrix and cylindrical structure designs of the Negative Poisson's Ratio (NPR) metamaterial. The results indicate that the plane matrix NPR metamaterial design exhibits concurrent vertical and horizontal expansion when subjected to an external magnetic field. In contrast, the cylindrical structure demonstrates simultaneous axial and radial expansion under the same conditions. The preliminary findings demonstrate the considerable potential and practicality of the proposed methodology in the development of magnetically activated MIET devices, which offer biocompatibility, a diminished risk of adverse reactions, and enhanced therapeutic outcomes. Integrating ferromagnetic soft materials into mechanical metastructures unlocks promising opportunities for designing stents with adjustable mechanical properties, propelling the field towards more sophisticated minimally invasive vascular interventions.