ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025
High accuracy in lower limb alignment analysis using convolutional neural networks, with improvements needed for joint-level metrics.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Automated radiographic assessment of lower limb alignment using deep learning in a data-constrained clinical setting.BMC musculoskeletal disorders · 2025Article
- High accuracy in lower limb alignment analysis using convolutional neural networks, with improvements needed for joint-level metrics.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
- Use of Artificial Intelligence on Imaging and Preoperatory Planning of the Knee Joint: A Scoping Review.Medicina (Kaunas, Lithuania) · 2025Article
- Comparison of an AI-driven planning tool and manual radiographic measurements in total knee arthroplasty.Computational and structural biotechnology journal · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeEvaluation of long-leg standing radiographs (LSR) is a standardised procedure for analysis of primary or secondary deformities of the lower limbs. Deep-learning convolutional neural networks (CNN) offer the potential to enhance radiological measurement by increasing reproducibility and accuracy. This study aims to evaluate the measurement accuracy of an automated CNN-based planning tool (mediCAD® 7.0; mediCAD Hectec GmbH) of lower limb deformities.
methodsIn a retrospective single-centre study, 164 pre- and postoperative bilateral LSRs with uni- or bilateral posttraumatic knee arthritis undergoing total knee arthroplasty (TKA) were enroled. Alignment parameters relevant to knee arthroplasty and deformity correction were analysed independently by two observers and a CNN. The intraclass correlation coefficient (ICC) was used to evaluate the accuracy between observers and the CNN, which was further evaluated using absolute deviations, limits of agreement (LoA) and root mean square error (RMSE).
resultsCNN evaluation demonstrated high consistency in measuring leg length (ICC > 0.99) and overall lower limb alignment measures of mechanical tibio-femoral angle (mTFA) (ICC > 0.97; RMSE < 1.1°). The mean absolute difference between angular measurements were low for overall lower limb alignment (mTFA 0.49-0.61°) and high for specific joint angles (aMPFA 3.86-4.50°). Accuracy at specific joint angles like the mechanical proximal tibial angle (MPTA) and the mechanical lateral distal femur angle (mLDFA) varied between lower limbs with deformity, with and without TKA with greatest difference for TKA (ICC 0.22-0.85; RMSE 1.72-3.65°).
conclusionExcellent accuracy was observed between manual and automated measurements for overall alignment and leg length, but joint-level metrics need further improvement especially in case of TKA similar to other existing algorithms. Despite the observed deviations, the time-efficient nature of the algorithm improves the efficiency of the preoperative planning process. LEVEL OF EVIDENCE: Level IV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.