Evidence map›Paper›PMID 39308148›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

High accuracy in lower limb alignment analysis using convolutional neural networks, with improvements needed for joint-level metrics.

Christof Hoffmann, Fatih Göksu, Isabella Klöpfer-Krämer, Julius Watrinet, Philipp Blum, Sven Hungerer, Steffen Schröter, Fabian Stuby, Peter Augat, Julian Fürmetz

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Christof HoffmannDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Fatih GöksuDepartment of Orthopedics and Reconstructive Surgery, Diakonie Klinikum, GmbH Jung-Stilling-Krankenhaus, Siegen, Germany.
Isabella Klöpfer-KrämerDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Julius WatrinetDepartment of Orthopaedic Sports Medicine, Technical University, Munich, Germany.
Philipp BlumDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Sven HungererDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Steffen SchröterDepartment of Orthopedics and Reconstructive Surgery, Diakonie Klinikum, GmbH Jung-Stilling-Krankenhaus, Siegen, Germany.
Fabian StubyDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Peter AugatDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.
Julian FürmetzDepartment of Trauma Surgery, BG Trauma Center Murnau, Murnau, Germany.ORCID http://orcid.org/0000-0001-5529-1632

Funding

mediCAD
6 · The paper itself

Abstract

purposeEvaluation of long-leg standing radiographs (LSR) is a standardised procedure for analysis of primary or secondary deformities of the lower limbs. Deep-learning convolutional neural networks (CNN) offer the potential to enhance radiological measurement by increasing reproducibility and accuracy. This study aims to evaluate the measurement accuracy of an automated CNN-based planning tool (mediCAD® 7.0; mediCAD Hectec GmbH) of lower limb deformities.

methodsIn a retrospective single-centre study, 164 pre- and postoperative bilateral LSRs with uni- or bilateral posttraumatic knee arthritis undergoing total knee arthroplasty (TKA) were enroled. Alignment parameters relevant to knee arthroplasty and deformity correction were analysed independently by two observers and a CNN. The intraclass correlation coefficient (ICC) was used to evaluate the accuracy between observers and the CNN, which was further evaluated using absolute deviations, limits of agreement (LoA) and root mean square error (RMSE).

resultsCNN evaluation demonstrated high consistency in measuring leg length (ICC > 0.99) and overall lower limb alignment measures of mechanical tibio-femoral angle (mTFA) (ICC > 0.97; RMSE < 1.1°). The mean absolute difference between angular measurements were low for overall lower limb alignment (mTFA 0.49-0.61°) and high for specific joint angles (aMPFA 3.86-4.50°). Accuracy at specific joint angles like the mechanical proximal tibial angle (MPTA) and the mechanical lateral distal femur angle (mLDFA) varied between lower limbs with deformity, with and without TKA with greatest difference for TKA (ICC 0.22-0.85; RMSE 1.72-3.65°).

conclusionExcellent accuracy was observed between manual and automated measurements for overall alignment and leg length, but joint-level metrics need further improvement especially in case of TKA similar to other existing algorithms. Despite the observed deviations, the time-efficient nature of the algorithm improves the efficiency of the preoperative planning process. LEVEL OF EVIDENCE: Level IV.

Indexed as

Convolutional Neural NetworksKnee JointLower ExtremityOsteoarthritis, KneeAgedArthroplasty, Replacement, KneeFemaleHumansMaleMiddle AgedRadiographyReproducibility of ResultsRetrospective Studiesdeep learning convolutional neural networkleg deformitylong leg standing radiographsosteotomytotal knee arthroplasty

Identifiers

PMID39308148
PMCPMC12104771

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.