Evidence map›Paper›PMID 39308130›Full record

ArticleClinical and experimental dental research2024

Toward Wearables for Bruxism Detection: Voluntary Oral Behaviors Sound Recorded Across the Head Depend on Transducer Placement.

Mohammad Khair Nahhas, Jens Christoph Türp, Philippe Cattin, Nicolas Gerig, Elisabeth Wilhelm, Georg Rauter

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammad Khair NahhasBIROMED-Lab, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.ORCID 0009-0007-0791-9035
Jens Christoph TürpDivision of Temporomandibular Disorders and Orofacial Pain, Department of Oral Health and Medicine, University Center for Dental Medicine Basel UZB, Basel, Switzerland.
Philippe CattinCIAN, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Nicolas GerigBIROMED-Lab, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Elisabeth WilhelmDiscrete Technology and Production Automation, Engineering and Technology Institute Groningen, Faculty of Science and Engineering, University of Groningen, Groningen, The Netherlands.
Georg RauterBIROMED-Lab, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.

Funding

Department of Biomedical Engineering of the University of Basel.Werner Siemens Foundation
6 · The paper itself

Abstract

objectivesBruxism is a parafunctional orofacial behavior. For diagnosis, wearable devices that use sounds as biomarkers can be applied to provide the necessary information. Human beings emit various verbal and nonverbal sounds, making it challenging to identify bruxism-induced sounds. We wanted to investigate whether the acoustic emissions of different oral behaviors have distinctive characteristics and if the placement of the transducer has an impact on recording the sound signals. MATERIAL AND

methodsSounds from five oral behaviors were investigated: jaw clenching, teeth grinding, reading, eating, and drinking. Eight transducers were used; six were attached to the temporal, frontal, and zygomatic bones with the aid of medical tape, and two were integrated into two commercial earphones. The data from 15 participants were analyzed using time-domain energy, spectral flux, and zero crossing rate (ZCR).

resultsIn summary, all oral behaviors showed distinct characteristic features except jaw clenching, though there was a peak in the recording, possibly due to tooth tapping, before its expected onset. For teeth grinding, the transducer placement did not have a significant impact (p > 0.05) based on energy, spectral flux, and ZCR. For jaw clenching, the transducer placement had an impact with regard to spectral flux (p < 0.01). For reading and eating, the transducer placement had a significant impact with regard to energy (p < 0.05 for reading, p < 0.01 for eating), spectral flux (p < 0.001 for reading, p < 0.01 for eating), and ZCR (p < 0.001 for both reading and eating). For drinking, the transducer placement only had a significant impact with regard to ZCR (p < 0.01).

conclusionsWe were able to record the sounds of various oral behaviors from different locations on the head. However, the ears were an advantageous location to place the transducer, since they could compensate for various head movements and ear devices are socially tolerable.

Indexed as

BruxismTransducersWearable Electronic DevicesAdultDrinkingEatingFemaleHumansMaleSoundYoung Adultjaw clenchingsoundteeth grinding

Identifiers

PMID39308130
PMCPMC11417139

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked