Comparison of side-hole and step-tip catheters for patients requiring continuous renal replacement therapy in intensive care units: study protocol for a randomised controlled trial.

Zhifeng Zhou, Chen Liu, Yingying Yang, Fang Wang, Sheng Zhang, Ling Zhang, Ping Fu

Abstract readClinical Trial Protocol
In one paragraph

Article in BMJ open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhifeng Zhou *Department of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.
Chen Liu *Department of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.
Yingying YangDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.
Fang WangDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.
Sheng ZhangDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.
Ling ZhangDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China zhangling_crrt@163.com.ORCID 0000-0003-1155-4802
Ping FuDepartment of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn addition to various techniques involved in catheter insertion, catheter placement location, lumen diameter and operation and management during continuous renal replacement therapy (CRRT), the design of the tip and side holes, as well as the position of the tip of the catheter, can also impact catheter function. Side-hole and step-tip catheters are commonly used during CRRT. However, there is insufficient evidence comparing their efficacy for CRRT in critically ill patients. And the optimal position of the tip of catheters is not well studied and remains controversial. This study was conducted to assess whether using a step-tip catheter could reduce the rate of catheter dysfunction compared with a side-hole catheter and whether inserting a longer catheter could reduce the incidence of catheter dysfunction and increase catheter survival time. METHODS AND ANALYSIS: A prospective, open-label, three-arm, parallel-group, single-centre randomised controlled trial will be conducted at West China Hospital of Sichuan University in China. An estimated sample of 378 participants receiving CRRT treatment will be recruited. Eligible patients will be randomly assigned to three groups to receive different dialysis catheters for the initiation of CRRT at a 1:1:1 ratio via a central randomisation system: group A, side-hole catheters (11Fr, 200 mm; GDHK-1120; Baxter International Inc., Deerfield, Illinois); group B, step-tip catheters (13Fr, 200 mm; GDHK-1320; Baxter International Inc.) and group C, step-tip catheters (13Fr, 250 mm; GDHK-1325; Baxter International Inc.). The femoral vein is the only vascular access. All catheters will be inserted under the guidance of ultrasound using the Seldinger method to reduce complications and trauma related to catheter insertion. The primary outcomes are the occurrence of catheter dysfunction and catheter survival time. Outcome assessors and data analysts will be blinded. All data will be analysed according to the group randomly assigned by an intention-to-treat analysis, in which catheters with missing data for the primary outcomes would be excluded. ETHICS AND DISSEMINATION: The trial protocol has been approved by the Biomedical Research Ethics Committee of West China Hospital of Sichuan University (2023.1221). And the results will be published in peer-reviewed journals. TRIAL REGISTRATION NUMBER: ChiCTR2300075107.

Indexed as

Continuous Renal Replacement TherapyIntensive Care UnitsRandomized Controlled Trials as TopicCatheters, IndwellingChinaCritical IllnessEquipment DesignFemaleHumansMaleProspective StudiesDialysisNephrologyRandomized Controlled Trial

Identifiers

PMID39306351
PMCPMC11418563

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.