Fatigue lifetime of reduced-diameter implants placed in different bone models.

Pedro Henrique Wentz Tretto, Jason Alan Griggs, Kartikeya Singh Jodha, Yuanyuan Duan, Susana María Salazar Marocho, Alvaro Della Bona

Abstract read
In one paragraph

Article in Dental materials : official publication of the Academy of Dental Materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Screening dental implant design parameters for effect on the fatigue limit of reduced-diameter implants.Dental materials : official publication of the Academy of Dental Materials · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pedro Henrique Wentz TrettoPostgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Campus I - BR 285, Passo Fundo, RS 99052-900, Brazil. Electronic address: pedrotretto@gmail.com.
Jason Alan GriggsBiomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA. Electronic address: jgriggs@umc.edu.
Kartikeya Singh JodhaBiomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA. Electronic address: kjodha@umc.edu.
Yuanyuan DuanBiomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA. Electronic address: yduan@umc.edu.
Susana María Salazar MarochoBiomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505, USA. Electronic address: ssalazarmarocho@umc.edu.
Alvaro Della BonaPostgraduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Campus I - BR 285, Passo Fundo, RS 99052-900, Brazil. Electronic address: dbona@upf.br.

Funding

Design Optimization of Reduced-Diameter Implants in Simulated and Cadaver BoneR01DE026144 · NIDCR · UNIVERSITY OF MISSISSIPPI MED CTR · PI GRIGGS, JASON A · 2019 to 2023
$1.8M
Fatigue of Dental ImplantsR01DE017991 · NIDCR · UNIVERSITY OF MISSISSIPPI MED CTR · PI GRIGGS, JASON A · 2007 to 2011
$1.3M
NIDCR NIH HHS R01 DE017991NIDCR NIH HHS R01 DE026144NIH HHS DE026144
6 · The paper itself

Abstract

objectivesThis study assessed the fatigue lifetime of reduced-diameter implants placed in either bovine rib or polymer-based bone model.

methodsBovine ribs were classified according to the criteria proposed by Lekholm and Zarb and were analyzed for bone fraction. Fourteen dental implants (3.25 mm in diameter × 15 mm in length) were placed in bovine ribs used as a bone model. They were subjected to resonance frequency analysis. Stainless steel loading hemisphere caps were bonded on the abutments position at 30-degree angle and with a moment arm of 11 mm. Accelerated life testing using the step-stress method was conducted at 2 Hz with a stress ratio of 0.1 until fracture on a servo-hydraulic load frames machine (MTS). Results were compared with those of a previous study wherein implants were placed in a polymer-based bone model. Fatigue lifetime statistics (characteristic lifetime and Weibull modulus) of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined under an electron scanning microscope to determine the failure mode.

resultThe implants exhibited high stability quotient values (75.07 ± 3.81). Implants placed in bovine ribs showed better data dispersion and longer fatigue lifetime than those placed in polymer-based bone models, with no significant difference between groups. All fractures occurred in the implant body near the bone level and were indicative of fatigue fractures. SIGNIFICANCE: Bovine ribs appear to be a more suitable material for accelerated life testing than the polymer-based material because of better data dispersion.

Indexed as

Dental ImplantsRibsAnimalsCattleDental Prosthesis DesignDental Restoration FailureDental Stress AnalysisMaterials TestingMicroscopy, Electron, ScanningResonance Frequency AnalysisDental ImplantsDental implantsFatigue fracturesFractographic analysis

Identifiers

PMID39304478
PMCPMC13391214

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.