Evidence map›Paper›PMID 39301770›Full record

ArticleMagnetic resonance in medicine2025

Calibration-free whole-brain CEST imaging at 7T with parallel transmit pulse design for saturation homogeneity utilizing universal pulses (PUSHUP).

Yannik Völzke, Suzan Akbey, Daniel Löwen, Eberhard Daniel Pracht, Rüdiger Stirnberg, Vincent Gras, Nicolas Boulant, Moritz Zaiss, Tony Stöcker

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. 10.5 T In Vivo Head Imaging With Universal RF Shimming.Magnetic resonance in medicine · 2026
    Article
  3. Article
  4. Article
  5. Rapid and simplified post-processing for simultaneousMagnetic resonance in medicine · 2025
    Article
  6. MPRAGEMagnetic resonance in medicine · 2025
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yannik VölzkeGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.ORCID 0000-0002-3907-5494
Suzan AkbeyGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
Daniel LöwenGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.ORCID 0000-0003-3709-9297
Eberhard Daniel PrachtGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.ORCID 0009-0008-4883-9709
Rüdiger StirnbergGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.ORCID 0000-0001-7021-1063
Vincent GrasCNRS, NeuroSpin, Baobab, Université Paris-Saclay, Commissariat à' l'Energie Atomique, Gif sur Yvette, France.ORCID 0000-0002-4997-2738
Nicolas BoulantCNRS, NeuroSpin, Baobab, Université Paris-Saclay, Commissariat à' l'Energie Atomique, Gif sur Yvette, France.ORCID 0000-0003-2144-2484
Moritz ZaissInstitute of Neuroradiology, Institute of Neuroradiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.ORCID 0000-0001-9780-3616
Tony StöckerGerman Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.ORCID 0000-0002-8946-9141

Funding

Bundesministerium für Bildung und Forschung 01ED2109AHorizon 2020 Framework Programme 885876
6 · The paper itself

Abstract

purposeChemical exchange saturation transfer (CEST) measurements at ultra-high field (UHF) suffer from strong saturation inhomogeneity. Retrospective correction of this inhomogeneity is possible to some extent, but requires a time-consuming repetition of the measurement. Here, we propose a calibration-free parallel transmit (pTx)-based saturation scheme that homogenizes the saturation over the imaging volume, which we call PUlse design for Saturation Homogeneity utilizing Universal Pulses (PUSHUP). THEORY: Magnetization transfer effects depend on the saturation

methodsPUSHUP was combined with a whole-brain three-dimensional-echo planar imaging (3D-EPI) readout. Two PUSHUP saturation modules were calculated by either applying whole-brain or cerebellum masks to the database maps. The saturation homogeneity and the group mean CEST amplitudes were calculated for different

resultsIn contrast to CP saturation, where accurate CEST maps were impossible to obtain in the cerebellum, even with extensive

conclusionThe presented method allows for homogeneous whole-brain CEST imaging at 7 Tesla without the need of a repetition-based

Indexed as

AlgorithmsBrainImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingAdultCalibrationFemaleHumansMaleCESTmagnetization transferparallel transmitultra‐high fielduniversal pulses

Identifiers

PMID39301770
PMCPMC11604840

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.