Evidence map›Paper›PMID 39301500›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2024

Design Optimization of A Triple-Layer Flat-Panel Detector for Three-Material Decomposition.

Xiao Jiang, Matthew Tivnan, Xiaoxuan Zhang, J Webster Stayman, Grace J Gang

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Quantitative Enhancement of Spectral Imaging in Photon-Counting CT via Dynamic Energy Thresholding.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  2. Article
  3. Performance of Dual-Layer Flat-Panel Detectors.Diagnostics (Basel, Switzerland) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiao JiangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Matthew TivnanDepartment of Radiology, Harvard Medical School/Massachusetts General Hospital, Boston MA, 02114, USA.
Xiaoxuan ZhangDepartment of Radiology, University of Pennsylvania, Philadelphia PA, 19104, USA.
J Webster StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Grace J GangDepartment of Radiology, University of Pennsylvania, Philadelphia PA, 19104, USA.

Funding

Patient-specific, high-sensitivity spectral CT for assessment of pancreatic cancerR01EB030494 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE, NOËL, PETER B · 2021 to 2024
$2.4M
NIBIB NIH HHS R01 EB030494
6 · The paper itself

Abstract

Spectral radiography and fluoroscopy with multi-layer flat-panel detectors (FPD) is being actively investigated in a range of clinical applications. For applications involving contrast administration, maximal contrast resolution is achieved when overlaying background anatomy is completely removed. This calls for three-material decomposition (soft tissue, bone, and contrast) enabled by measurements in three energy channels. We have previously demonstrated the feasibility of such decomposition using a triple-layer detector. While algorithmic solutions can be adopted to mitigate noise in the material basis images, in this work, we seek to fundamentally improve the conditioning of the problem through optimized system design. Design parameters include source voltage, the thickness of the top two CsI scintillators, and the thickness of two copper interstitial filters. The design objective is to minimize noise in the basis image containing contrast, chosen as gadolinium in this work to improve separation from bone. The optimized design was compared with other designs with unoptimized scintillator thickness and/or without interstitial filtration. Results show that CsI thickness optimization and interstitial filtration can significantly reduce noise in the gadolinium image by 35.7% and 42.7% respectively within a lung ROI, which in turn boosts detectability of small vessels. Gadolinium and bone signals are separated in all cases. Visualization of coronary vessels is enabled by the combining optimized system design and regularization. Results from this work demonstrate that three-material decomposition can be significantly improved with system design optimization. Optimized designs obtained from this work can inform imaging techniques selection and triple-layer detector fabrication for spectral radiography.

Identifiers

PMID39301500
PMCPMC11412191

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.