Evidence map›Paper›PMID 39301437›Full record

ArticleInternational journal on magnetic particle imaging2023

Temperature-Dependent Changes in Resolution and Coercivity of Superparamagnetic and Superferromagnetic Iron Oxide Nanoparticles.

Owen Doyle, Jacob Bryan, Melissa Kim, Chinmoy Saayujya, Sophie Nazarian, Javier Mokkarala-Lopez, Renesmee Kuo, Mariam Yousuf, Prashant Chandrasekharan, Benjamin Fellows and 1 more

Abstract read
In one paragraph

Article in International journal on magnetic particle imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Owen DoyleDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-7074-4756
Jacob BryanDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0001-7102-2192
Melissa KimDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.
Chinmoy SaayujyaDepartment of Electrical Engineering and Computer Sciences, UC Berkeley, Berkeley CA, USA.ORCID 0000-0001-6125-8986
Sophie NazarianDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.
Javier Mokkarala-LopezDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.
Renesmee KuoDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-9309-2914
Mariam YousufDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-1201-1546
Prashant ChandrasekharanDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-6139-1979
Benjamin FellowsDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-8404-7281
Steven ConollyDepartment of Bioengineering, UC Berkeley, Berkeley CA, USA.ORCID 0000-0002-3310-6085

Funding

Ten-Fold Resolution Boost for Magnetic Particle Imaging with Applications to Rapid, Non-Invasive Imaging of CAR-T Cell Therapies, Stroke, GI Bleeds and Pulmonary EmbolismsU01EB034694 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI STEVEN M CONOLLY · 2023 to 2026
$2.7M
In Vivo Therapeutic Cell Tracking by Advanced Magnetic Particle ImagingR01EB024578 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI CONOLLY, STEVEN M · 2017 to 2020
$2.2M
Pre-clinical quantitation of ovarian cancer tumor burden using Magnetic Particle Imaging and non-dilutive cell labelingR01EB019458 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI BELL, CALEB B., CONOLLY, STEVEN M · 2015 to 2018
$1.9M
Color MPI as a novel method for in vivo assessment of magnetic nanoparticle dynamics and bindingR44EB029877 · NIBIB · MAGNETIC INSIGHT, INC. · PI GOODWILL, PATRICK · 2020 to 2021
$1.6M
Magnetic Particle Imaging for High-Resolution Functional Brain ImagingR01EB029822 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI CONOLLY, STEVEN M · 2020 to 2020
$815k
NIBIB NIH HHS R01 EB019458NIBIB NIH HHS R01 EB024578NIBIB NIH HHS R01 EB029822NIBIB NIH HHS R44 EB029877NIBIB NIH HHS U01 EB034694
6 · The paper itself

Abstract

Magnetic Particle Imaging (MPI) is a tracer-based imaging modality with immense promise as a radiation-free alternative to nuclear medicine imaging techniques. Nuclear medicine requires "hot chemistry" wherein radioactive tracers must be synthesized on-site, requiring expensive infrastructure and labor costs. MPI's magnetic nanoparticles, superparamagnetic iron oxide nanoparticles (SPIOs), have no significant signal decay over time which removes cost barriers associated with nuclear medicine studies such as FDG-PET. While SPIOs are the current industry standard MPI tracer, recent developments in synthesizing superferromagnetic iron oxide nanoparticles (SFMIOs) and high resolution SPIOs (HR-SPIOs), a new class of nanoparticle with almost zero coercivity, have yielded a 30-fold improvement in resolution (0.4 mT) and SNR. To better understand the long-term performance of these new nanoparticles, this investigation reports changes in SPIO (VivoTrax Plus), HR-SPIO, and SFMIO resolution, along with SFMIO coercivity, at low temperatures (-2, 2 °C) and room temperature (18-22 °C) over 12 weeks. We find that changes in HR-SPIO resolution are more sensitive to storage temperature than SFMIOs. Additionally, we observe no appreciable difference in SFMIO coercivity between the two temperatures over time. These results can inform research on optimizing tracer synthesis while lending practical information to future hospitals about the highly accessible conditions for the transit and storage of tracers.

Identifiers

PMID39301437
PMCPMC11412576

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.