ArticleBMC ophthalmology2024

Comparison of measurements and calculated lens power using three biometers: a Scheimpflug tomographer with partial coherence interferometry and two swept source optical coherence tomographers.

Robert Edward T Ang, Benedict L Estolano, Paulo Hector C Luz, Maria Isabel N Umali, Michelle Marie Q Araneta, Emerson M Cruz

Abstract readComparative Study
In one paragraph

Article in BMC ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Robert Edward T AngAsian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines. rtang@asianeyeinstitute.com.
Benedict L EstolanoCardinal Santos Medical Center, 10 Wilson St., Greenhills West, San Juan City, 1502, Philippines.
Paulo Hector C LuzAsian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
Maria Isabel N UmaliAsian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
Michelle Marie Q AranetaAsian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.
Emerson M CruzAsian Eye Institute, 8th Floor PHINMA Plaza Bldg., Hidalgo Drive, Rockwell Center, Makati City, 1200, Philippines.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae.

methodsThis was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula.

resultsThe study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power.

conclusionsThe Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.

Indexed as

BiometryInterferometryLenses, IntraocularTomography, Optical CoherenceAdultAgedAged, 80 and overAnterior ChamberAxial Length, EyeCross-Sectional StudiesFemaleHumansMaleMiddle AgedOptics and PhotonicsRefraction, OcularANTERIONAnterior chamber depthAxial lengthBiometryCataract surgeryIntraocular lens power calculationIOLMaster 700KeratometryPentacam AXL Wave

Identifiers

PMID39300358
PMCPMC11412051

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.