Evidence map›Paper›PMID 39297928›Full record

ArticleUpdates in surgery2024

Robotic preperitoneal extended totally extraperitoneal (R-PeTEP) technique description for ventral hernia repair: preliminary results.

Luis Arias-Espinosa, Christiano M Claus, Flavio Malcher, Héctor Alí Valenzuela Alpuche

Abstract read
PubMed Publisher
In one paragraph

Article in Updates in surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Falciform Ligament Laparoscopic Approach for Preperitoneal Ventral Hernia Repair.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Luis Arias-EspinosaDivision of General Surgery, New York University Langone Health, 550 First Ave, New York City, NY, 10016, USA. luisariasespinosa@gmail.com.ORCID http://orcid.org/0000-0001-5983-6687
Christiano M ClausMinimally Invasive Surgery Department, Nossa Semhora das Graças Hospital, Curitiba, Brazil.
Flavio MalcherDivision of General Surgery, New York University Langone Health, 550 First Ave, New York City, NY, 10016, USA.
Héctor Alí Valenzuela AlpucheDepartment of General Surgery, Hospital Ángeles del Carmen, Jalisco, Mexico.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTransabdominal preperitoneal (TAPP) ventral hernia repair requires incising the peritoneum from within the abdominal cavity, developing a flap, and placing a reinforcing mesh after fascial closure from the preperitoneal space. We present a novel adaptation to this technique that allows placement of preperitoneal mesh without entering the abdominal cavity. The robotic totally extra- and preperitoneal (R-PeTEP) access for ventral hernia repair is best suited for small to moderate sized ventral hernias with concomitant diastasis recti.

methodsOur study is a retrospective review of all patients who underwent R-PeTEP from December 2022 to November 2023. A comprehensive description of the surgical technique is included. Patient demographics, hernia characteristics, as well as clinical outcomes are described.

resultsA total of 25 patients underwent R-PeTEP for ventral hernia repair with diastasis recti plication. The median age was 55 years (IQR 43.5-63) and 92% (n = 23) were male. The median ASA score was 2 (IQR 1-2) and the median BMI was 30.4 (IQR 29.3-32.8) with 64% (n = 16) percent having a BMI ≥ 30. Median hernia width was 3 cm (IQR 3-4), with a median diastasis recti width of 4 cm (IQR 2.6-4) and length of 15 cm (IQR 11.8-16). The median operative time was 120 min (IQR 116-134). All repairs were reinforced with permanent mesh. Sixty-eight percent of the patients (n = 17) were discharged on the same day. With a median follow-up of 30 days (IQR 16-107), 8% (n = 2) seromas, 16% (n = 4) developed clinically insignificant hematomas, and one patient (4%) developed ileus that was managed conservatively.

conclusionThis study establishes the feasibility and safety of R-PeTEP, which provides direct access to the preperitoneal space, avoiding disruption to the posterior rectus sheath, possibly reducing neurovascular bundle injuries, and omitting entry to the abdominal cavity. R-PeTEP facilitates wide flap creation for prosthetic overlap and allows for posterior plication of diastasis recti with little to no mesh fixation with overall excellent preliminary clinical outcomes.

Indexed as

Hernia, VentralHerniorrhaphyPeritoneumRobotic Surgical ProceduresSurgical MeshAdultFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeDiastasis rectieTEP Rives-StoppaExtraperitonealPreperitonealRobotic ventral hernia repair

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.