Evidence map›Paper›PMID 39296631›Full record

ArticleVeterinarni medicina2024

Comparison of two methods of measuring the urinary protein concentration for the determination of the urinary protein to creatinine ratio in various animal species.

Simona Kovarikova, Jana Blahova, Ivana Vanova, Petr Marsalek

Abstract read
In one paragraph

Article in Veterinarni medicina, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Simona KovarikovaDepartment of Animal Welfare and Protection and Veterinary Public Health, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences, Brno, Czech Republic.ORCID 0000-0003-0045-6326
Jana BlahovaDepartment of Animal Welfare and Protection and Veterinary Public Health, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences, Brno, Czech Republic.
Ivana VanovaDepartment of Physiology, Faculty of Veterinary Medicine, University of Veterinary Sciences, Brno, Czech Republic.
Petr MarsalekDepartment of Animal Welfare and Protection and Veterinary Public Health, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences, Brno, Czech Republic.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Determination of the urinary protein-to-creatinine ratio (UPC) is an important tool in the quantification of proteinuria in animals. However, the result may be affected by the different methods of determining the urinary protein concentration. The aim of this study was to compare the turbidimetric method using benzethonium chloride and the colorimetric method using pyrogallol red in the measurement of the urinary protein concentration in dogs, cats, guinea pigs and horses. A total of 464, 192, 216 and 119 urine samples from dogs, cats, guinea pigs and horses were examined in the study, respectively. The group consisted of animals of both sexes and different ages, and, in the dogs and cats, it included both healthy animals and those with various health problems. In the group of horses and guinea pigs, only clinically healthy animals were included. A total of 347, 185, 103 and 100 samples from the dogs, cats, guinea pigs and horses were used in the statistical analysis; the other values were excluded as they were below the detection limit. According to the Passing-Bablok analysis, there was a significant constant and proportional difference in the horses. In the dogs, cats and guinea pigs, there was a significant constant difference, but no proportional difference. The Bland-Altman method showed significant bias between the two methods in the horses and cats, but not in the dogs and guinea pigs. In the dogs and cats, the agreement between the two methods was tested and expressed as Cohen's kappa (κ). In the cats, it was almost perfect for the proteinuric samples (κ = 0.823 3) and significant for the non-proteinuric samples (κ = 0.804 9). In the dogs, the agreement was significant for the non-proteinuric samples (κ = 0.621 5) and only moderate for the proteinuric samples (κ = 0.527 5). The influence of the method used to determine the urinary protein concentration should be taken into account when evaluating the UPC. Repeated examinations in one patient should be performed with the same method.

Indexed as

catdogguinea pighorseproteinuriaUPC

Identifiers

PMID39296631
PMCPMC11406498

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.