Evidence map›Paper›PMID 39296394›Full record

ArticleBiomedical optics express2024

Rapid, sensitive and multiplexed detection of SARS-CoV-2 viral nucleic acids enabled by phase-based surface plasmon resonance of metallic gratings.

Shuai Sun, Yuanyuan Zhao, Yuxuan Hao, Pan Xue, Xiaoyang Guo, Wei Zhang, Chunxiang Zhang, Qiongdi Zhang, Wenhua Zhou, Hock Chun Ong and 4 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Shuai SunCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Yuanyuan ZhaoCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Yuxuan HaoInterface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Pan XueInterface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Xiaoyang GuoCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Wei ZhangCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Chunxiang ZhangCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Qiongdi ZhangInterface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Wenhua ZhouInterface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Hock Chun OngDepartment of Physics, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China.
Xuefeng YuInterface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Zeren LiCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.
Jia LiCenter for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China.ORCID https://orcid.org/0000-0002-2270-9876
Jianquan YaoKey Laboratory of Opto-Electronics Information Technology (Tianjin University), Ministry of Education, School of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.ORCID https://orcid.org/0000-0003-3105-4370

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A rapid, sensitive and easy-to-implement approach is proposed for the detection of pathogenic nucleic acids based on phase-based plasmonic spectroscopy of metallic gratings. The plasmonic sensors were fabricated using interference lithography and functionalized with single-stranded DNA probes to specific target SARS-CoV-2. The biosensor achieved the detection of 40 fM viral nucleic acids within 5 min; furthermore, a detection capability of 1 aM (0.6 copies/µL) was acquired when combining with the recombinase polymerase amplification. Additionally, the multiplexed sensing system was demonstrated to simultaneously detect three genomic sequences on a single sensor chip, thereby enhancing diagnostic accuracy and enabling high-throughput detection.

Identifiers

PMID39296394
PMCPMC11407254

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.