Evidence map›Paper›PMID 39296035›Full record

ArticleHeliyon2024

Development of biomaterial composite hydrogel as a passive sampler with potential application in wastewater-based surveillance.

Orlando de la Rosa, Alberto Aguayo-Acosta, Hiram Martín Valenzuela-Amaro, Edgar Ricardo Meléndez-Sánchez, Juan Eduardo Sosa-Hernández, Roberto Parra-Saldívar

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Orlando de la RosaTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.
Alberto Aguayo-AcostaTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.
Hiram Martín Valenzuela-AmaroTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.
Edgar Ricardo Meléndez-SánchezTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.
Juan Eduardo Sosa-HernándezTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.
Roberto Parra-SaldívarTecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Mexico.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nowadays, the need to track fast-spreading infectious diseases has raised due to the recent COVID-19 disease pandemic. As a response, Wastewater-based Surveillance (WBS) has emerged as an early detection and disease tracking method for large populations that enables a comprehensive overview of public health allowing for a faster response from public health sector to prevent large outbreaks. The process to achieve WBS requires a highly intensive sampling strategy with either expensive equipment or trained personnel to continuously sample. The sampling problem can be addressed by passive sampler development. Chitosan-based hydrogels are recognized for their capability to sample and remove various contaminants from wastewater, including metals, dyes, pharmaceuticals, among others. However, chitosan-based hydrogels unique characteristics, can be exploited to develop passive samplers of genetic material that can be a very valuable tool for WBS. This study aimed to develop a novel chitosan hydrogel formulation with enhanced characteristics suitable for use as a passive sampler of genetic material and its application to detect disease-causing pathogens present in wastewater. The study evaluates the effect of the concentration of different components on the formulation of a Chitosan composite hydrogel (Chitosan, Glutaraldehyde, Microcrystalline cellulose (MCC), and Polyethylene glycol (PEG)) on the hydrogel properties using a Box Hunter & Hunter experimental matrix. Hydrogels' weight, thickness, swelling ratio, microscopic morphology (SEM), FTIR assay, and zeta potential were characterized. The resulting hydrogel formulations were shown to be highly porous, positively charged (Zeta potential up to 35.80 ± 1.44 mV at pH 3) and with high water swelling capacity (up to 703.89 ± 15.00 %). Based on the results, a formulation from experimental design was selected and then evaluated its capacity to adsorb genetic material from a control spiked water with Influenza A virus synthetic vector. The adsorption capacity of the selected formulation was 4157.04 ± 64.74 Gene Copies/mL of Influenza A virus synthetic vector. The developed hydrogel showed potential to be used as passive sampler for pathogen detection in wastewater. However, deeper research can be conducted to improve adsorption, desorption and extraction techniques of genetic material from chitosan-hydrogel matrices.

Indexed as

Composite hydrogelGene adsorptionPassive samplerWastewater-based surveillance

Identifiers

PMID39296035
PMCPMC11407980

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked