Evidence map›Paper›PMID 39293088›Full record

ArticleClinical orthopaedics and related research2025

Is 18 F-fluoride PET/CT an Accurate Tool to Diagnose Loosening After Total Joint Arthroplasty?

Caroline Sköld, Jens Sörensen, Anders Brüggemann, Nils P Hailer

Abstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Current Uses for Medical Imaging With Orthopaedic Implant Technology.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Caroline SköldDepartment of Surgical Sciences/Orthopaedics, Uppsala University, Uppsala, Sweden.ORCID 0000-0002-2583-5448
Jens SörensenDepartment of Surgical Sciences/Nuclear Medicine and PET, Uppsala University, Uppsala, Sweden.
Anders BrüggemannDepartment of Surgical Sciences/Orthopaedics, Uppsala University, Uppsala, Sweden.ORCID 0000-0002-3600-253
Nils P HailerDepartment of Surgical Sciences/Orthopaedics, Uppsala University, Uppsala, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSeveral studies using positron emission tomography (PET) show highly elevated periprosthetic bone uptake of fluorine-18 sodium fluoride ( 18 F-fluoride), suggestive of implant loosening after arthroplasty. Focus so far has been on qualitative but not on quantitative assessment. There is also a lack of intraoperative confirmation of preoperative 18 F-fluoride PET findings. Although the method seems to have acceptable accuracy and high sensitivity, an attempt to improve the specificity and an overall validation of the method appear warranted. QUESTIONS/PURPOSES: (1) Is there a difference in 18 F-fluoride uptake around loose versus well-fixed THA and TKA components? (2) Can 18 F-fluoride uptake measures provide a threshold that differentiates loose from well-fixed implants undergoing revision for a variety of septic and aseptic indications? (3) In a population restricted to THA and TKA undergoing revision for aseptic indications, can measurement of 18 F-fluoride uptake still distinguish loose from well-fixed components? (4) What is the interrater reliability of measuring 18 F-fluoride uptake?

methodsThis was a retrospective assessment of a diagnostic test, 18 F-fluoride PET/CT, which was performed prior to revision surgery. We included 63 patients with 31 THAs and 32 TKAs. Sixty-five percent of patients were female, and the mean age at 18 F-fluoride PET/CT was 66 years. The THA had different modes of fixation (cemented, cementless, and hybrid; 45%, 32%, and 23%, respectively), whereas all TKAs were cemented. Imaging was conducted using routine protocols 1 hour after tracer injection. The interobserver reproducibility was analyzed using Spearman rank correlations and Bland-Altman analyses. Two independent observers were trained separately by a nuclear physician to measure maximal periprosthetic standardized uptake values (SUV max ) for each arthroplasty component (n = 126). Findings at surgery (whether the components were well fixed or loose, as well as the presence or absence of infection) were used as a reference. Presence of periprosthetic joint infection was retrospectively determined based on the criteria suggested by the European Bone and Joint Infection Society (EBJIS): clinical features in combination with blood analysis, synovial fluid cytologic analysis, and microbiology test results. Receiver operating characteristic (ROC) curves were plotted to assess the area under the curve (AUC) for each investigated component separately, indicating suitable SUV max thresholds that differentiate loose from well-fixed components. After excluding patients with confirmed or suspected PJI per the EBJIS criteria (n = 12), the above analysis was repeated for the remaining patients with aseptic loosening (n = 51).

resultsWe found higher 18 F-fluoride uptake around loose versus well-fixed components in all but femoral TKA components (median [range] SUV max for well-fixed versus loose THA cups 10 [7 to 30] versus 22 [6 to 64], difference of medians 12; p = 0.003; well-fixed versus loose TKA femoral components 14 [4 to 41] versus 19 [9 to 42], difference of medians 5; p = 0.38). We identified favorable ROC curves for all investigated components except femoral TKA components (THA cups AUC 0.81 [best threshold 13.9]; THA femoral stems AUC 0.9 [best threshold 17.3]; femoral TKA components AUC 0.6 [best threshold 14.3]; tibial TKA components AUC 0.83 [best threshold 15.8]). 18 F-fluoride was even more accurate at diagnosing loosening when we limited the population to those patients believed not to have prosthetic joint infection (THA cups AUC 0.87 [best threshold 14.2]; THA femoral stems AUC 0.93 [best threshold 15.0]; femoral TKA components AUC 0.65 [best threshold 15.8]; tibial TKA components AUC 0.86 [best threshold 14.7]). We found strong interrater correlation when assessing SUV max values, with Spearman ρ values ranging from 0.96 to 0.99 and Bland-Altman plots indicating excellent agreement between the two independent observers.

conclusionMeasuring SUV max after 18 F-fluoride PET/CT is a useful adjunct in the diagnostic evaluation for suspected implant loosening after THA and TKA. The method appears to be both accurate and reliable in diagnosing implant loosening for all components except femoral TKA components. In a real-world mixed population with both low-grade infection and aseptic loosening, the method seems to be fairly easy to learn and helpful to subspecialized arthroplasty clinicians. When infection can be ruled out, the method probably performs even better. Further prospective studies are warranted to explore the reason why femoral TKA component loosening was more difficult to ascertain using this novel technique. LEVEL OF EVIDENCE: Level III, diagnostic study.

Indexed as

Arthroplasty, Replacement, HipArthroplasty, Replacement, KneeFluorine RadioisotopesHip JointHip ProsthesisKnee ProsthesisPositron Emission Tomography Computed TomographyProsthesis FailureRadiopharmaceuticalsAgedAged, 80 and overFemaleHumansMaleMiddle AgedObserver VariationFluorine-18Fluorine RadioisotopesRadiopharmaceuticals

Identifiers

PMID39293088
PMCPMC11828004

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.