A novel miniaturized roller pump circuit for simulation of extracorporeal circulation.

Anders K Hjärpe, Anders Jeppsson, Lukas Lannemyr, Fredrik Pernbro, Camilla Hesse, Birgitta Romlin

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anders K HjärpeDepartment of Perfusion, Sahlgrenska University Hospital, Gothenburg, Sweden.ORCID 0000-0001-8914-3312
Anders JeppssonDepartment of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.ORCID 0000-0003-2356-2295
Lukas LannemyrDepartment of Anaesthesia and Intensive Care, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID 0000-0002-8280-5210
Fredrik PernbroDepartment of Anaesthesia and Intensive Care, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID 0000-0003-0350-2973
Camilla HesseDepartment of Clinical Immunology and Transfusion Medicine (KITM), Sahlgrenska University Hospital, Gothenburg, Sweden.ORCID 0000-0001-8766-7104
Birgitta RomlinDepartment of Anaesthesia and Intensive Care, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.ORCID 0000-0002-8187-9760

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesExtracorporeal circulation induces pronounced effects on haemostasis and rheology. To study these, an ex vivo simulation model is an attractive alternative but often requires large amounts of blood. We sought to create a miniaturized roller pump circuit requiring minimal amounts of blood and to test if the circuit could be used to compare coagulation, platelet function and blood rheology between a dextran-based and a crystalloid-based priming solution.

methodsA miniaturized roller pump circuit requiring only 27 ml of blood was created. Blood samples from 8 cardiac surgery patients were mixed with either a dextran-based or a crystalloid-based solution and circulated for 60 min. Coagulation was assessed by rotational thromboelastometry, and platelet function by impedance aggregometry and flow cytometry, before and at 5 and 60 min of circulation.

resultsA time-dependent impairment of coagulation was observed in both groups. Maximum clot firmness was lower with dextran-based than with crystalloid-based priming at 5 min (HEPTEM 37 ± 4 vs 43 ± 4 mm, P < 0.001; EXTEM 37 ± 4 vs 43 ± 4 mm, P < 0.001; FIBTEM 3 ± 2 vs 9 ± 2 mm, P < 0.001) and at 60 min (HEPTEM 29 ± 9 vs 38 ± 5 mm, P < 0.001; EXTEM 30 ± 7 vs 39 ± 5 mm, P < 0.001; FIBTEM 3 ± 2 vs 8 ± 3 mm, P = 0.002). The EXTEM clotting time was longer with dextran-based solution at 5 (109 ± 19 vs 63 ± 7 sec, P < 0.001) and at 60 min (176 ± 72 vs 73 ± 7 sec, P = 0.004).

conclusionsThe novel miniaturized roller pump circuit can be used to mimic extracorporeal circulation for selected research questions. Dextran-based priming caused a significant impairment in haemostasis compared with a standard crystalloid solution.

Indexed as

Cardiopulmonary bypassCoagulationEx vivo simulationPlatelet aggregationPriming solution Thromboelastometry

Identifiers

PMID39292542
PMCPMC11422619

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.