ArticleHardwareX2024
Robust and low-cost open-source device for detecting infectious microorganisms by loop-mediated isothermal amplification.
Article in HardwareX, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Loop-Mediated Isothermal Amplification (LAMP) is a useful technique for detecting infectious microorganisms in human fluids since it performs similarly to conventional PCR, the results are obtained faster and no thermocyclers or complex devices are required. Since only two isothermal blocks (95 °C to lyse cells and 65 °C for DNA amplification) are needed, LAMP is particularly suited for applications in Low- and Middle-Income Countries (LMICs). To validate such assumption, we first designed and tested Arduino-controlled LAMP thermoblocks to process a considerable number of samples simultaneously with a low-energy consumption to enable routine use under worst-case conditions (no main power source and low ambient temperatures). The thermoblocks were tested when battery-powered at temperature down to 5 °C, showing high stability in well temperatures (<0.8 °C). The charge required for both thermoblocks to simultaneously achieve the target temperatures after switching on and to keep their working temperatures were 4.1 A·h and 2.4 A·h/h, respectively. Second, we implemented a low-cost viewer with LEDs and filters to detect the fluorescent LAMP reaction. All the components required for the instrument are for general purpose and readily available by e-commerce. Thus, the LAMP device allows for considerable autonomy by using a typical car battery in rural and itinerant healthcare or field hospitals in LMICs, even under difficult environmental conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.