Evidence map›Paper›PMID 39291153›Full record

ArticleDigital health

Assessment of health technology acceptability for remote monitoring of patients with COVID-19: A measurement model for user perceptions of pulse oximeters.

Andrea Torres-Robles, Melissa Baysari, Karen Allison, Miranda Shaw, Owen Hutchings, Warwick J Britton, Andrew Wilson, Simon K Poon

Abstract read
In one paragraph

Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Andrea Torres-RoblesFaculty of Medicine and Health, The University of Sydney, Sydney, Australia.ORCID https://orcid.org/0000-0002-8751-5706
Melissa BaysariFaculty of Medicine and Health, The University of Sydney, Sydney, Australia.
Karen AllisonFaculty of Medicine and Health, The University of Sydney, Sydney, Australia.
Miranda ShawRoyal Prince Alfred Virtual Hospital, Sydney Local Health District, Camperdown, Australia.
Owen HutchingsRoyal Prince Alfred Virtual Hospital, Sydney Local Health District, Camperdown, Australia.
Warwick J BrittonSydney Local Health District, Camperdown, Sydney, Australia.
Andrew WilsonMenzies Centre for Health Policy and Economics, The University of Sydney, Sydney, Australia.ORCID https://orcid.org/0000-0002-1809-7846
Simon K PoonSchool of Computer Science, University of Sydney, Sydney, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aims to develop a measurement model for health technology acceptability using a theoretical framework and a range of validated instruments to measure user experience, acceptance, usability, health and digital health literacy. Methods: A cross-sectional evaluation study using a mixed-methods approach was conducted. An online survey was administered to patients who used a pulse oximeter in a virtual hospital setting during COVID-19. The model development was conducted in three steps: (1) exploratory factor analysis for conceptual model development, (2) measurement model confirmation through confirmatory factor analysis followed by structural equation modelling and (3) test of model external validity on four outcome measures. Finally, the different constructs of the developed model were used to compare two types of pulse oximeters by measuring the standardised scores. Results: Two hundred and two participants were included in the analysis, 37.6% were female and the average age was 53 years (SD:15.38). A four-construct model comprising Task Load, Affective Attitude, Self-Efficacy and Value of Use (0.636-0.857 factor loadings) with 12 items resulted from the exploratory factor analysis and yielded a good fit (RMSEA = .026). Health and digital health literacy did not affect the overall reliability of the model. Frustration, performance, trust and satisfaction were identified as outcomes of the model. No significant differences were observed in the acceptability constructs when comparing the two pulse oximeter devices. Conclusions: This article proposes a model for the measurement of the acceptability of health technologies used by patients in a remote care setting based on the use of a pulse oximeter in COVID-19 remote monitoring.

Indexed as

COVID-19health technology acceptability evaluationmeasurement model developmentpulse oximeterRemote patient monitoringuser experienceuser perception of acceptability

Identifiers

PMID39291153
PMCPMC11406631

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.