Evidence map›Paper›PMID 39290520›Full record

ArticleEuropean heart journal. Case reports2024

Rest, replace, and recover: TandemHeart to transcatheter aortic valve replacement-a case report.

Syed H Haq, Sidra R Shah, David Eapen, Anna Kleman, Mallory Knous, Amanda Laird, William Cole, Sandeep M Patel

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Syed H HaqDepartment of Internal Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.
Sidra R ShahDepartment of Internal Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.ORCID https://orcid.org/0000-0001-6122-3484
David EapenDepartment of Internal Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.
Anna KlemanStructural Heart & Intervention Center, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.
Mallory KnousDepartment of Critical Care Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.
Amanda LairdDepartment of Critical Care Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.ORCID https://orcid.org/0000-0002-2939-6825
William ColeDepartment of Critical Care Medicine, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.
Sandeep M PatelStructural Heart & Intervention Center, Bon Secours Mercy Health-St. Rita's Medical Center, 730 W Market Street, Lima, OH 45801, USA.ORCID https://orcid.org/0000-0003-1912-943X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Severe aortic stenosis (AS) can present insidiously, with the end stages resulting in significant valvular-induced cardiomyopathy and can lead to cardiogenic shock (CS). Such cases result in a myriad of complex manifestations and are often associated with a poor prognosis. These patients require emergent cardiac evaluation and valvular intervention. Unfortunately, the immediate nature of the CS provides little time for a detailed valvular evaluation. Possible management involves use of mechanical circulatory support (MCS) prior to urgent transcatheter aortic valve replacement (TAVR). Case summary: The patient was a 70-year-old female who developed refractory CS, and acute decompensated heart failure was complicated by AV block secondary to severe AS. Due to progressively worsening haemodynamics, the need for MCS for cardiovascular support and eventual valve replacement resulted in the decision to pursue TandemHeart® (TH; LivaNova Inc, Pittsburgh, PA, USA). We discuss the novel implementation of the TH as a means of bridging to TAVR. Discussion: TandemHeart system provides the benefits of improving haemodynamic support in CS while allowing unencumbered access to the stenotic valve for balloon aortic valvuloplasty (BAV) or TAVR. In our evaluation, we discuss the utilization and benefits associated with TH to TAVR in allowing for cardiac rest, replacement of the valve, and recovery of left ventricular function.

Indexed as

Cardiogenic ShockCase reportTandemHeart®Transcatheter aortic valve replacement

Identifiers

PMID39290520
PMCPMC11407279

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.