Evidence map›Paper›PMID 39289317›Full record

ArticleInternational journal of computer assisted radiology and surgery2025

Robust unsupervised texture segmentation for motion analysis in ultrasound images.

Arnaud Brignol, Farida Cheriet, Jean-François Aubin-Fournier, Carole Fortin, Catherine Laporte

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Ultrasound innovations in diaphragm assessment: an integrative review of expanding clinical applications.European respiratory review : an official journal of the European Respiratory Society · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Arnaud BrignolDepartment of Electrical Engineering, École de technologie supérieure, 1100, Rue Notre-Dame Ouest, Montreal, QC, H3C 1K3, Canada. arnaud.brignol.1@ens.etsmtl.ca.ORCID http://orcid.org/0009-0003-4670-9701
Farida CherietDepartment of Computer Engineering and Software Engineering, Polytechnique Montréal, 2900, boul. Édouard-Montpetit, Montreal, QC, H3T 1J4, Canada.
Jean-François Aubin-FournierCentre de réadaptation Marie-Enfant du CHU Sainte-Justine, 5200, rue Bélanger Est, Montreal, QC, H1T 1C9, Canada.
Carole FortinFaculté de médecine, École de réadaptation, 6128, succursale Centre-ville, Montreal, QC, H3C 3J7, Canada.
Catherine LaporteDepartment of Electrical Engineering, École de technologie supérieure, 1100, Rue Notre-Dame Ouest, Montreal, QC, H3C 1K3, Canada.

Funding

CIHR PJT-156107Natural Sciences and Engineering Research Council of Canada 414043-2012
6 · The paper itself

Abstract

purposeUltrasound imaging has emerged as a promising cost-effective and portable non-irradiant modality for the diagnosis and follow-up of diseases. Motion analysis can be performed by segmenting anatomical structures of interest before tracking them over time. However, doing so in a robust way is challenging as ultrasound images often display a low contrast and blurry boundaries.

methodsIn this paper, a robust descriptor inspired from the fractal dimension is presented to locally characterize the gray-level variations of an image. This descriptor is an adaptive grid pattern whose scale locally varies as the gray-level variations of the image. Robust features are then located based on the gray-level variations, which are more likely to be consistently tracked over time despite the presence of noise.

resultsThe method was validated on three datasets: segmentation of the left ventricle on simulated echocardiography (Dice coefficient, DC), accuracy of diaphragm motion tracking for healthy subjects (mean sum of distances, MSD) and for a scoliosis patient (root mean square error, RMSE). Results show that the method segments the left ventricle accurately (

conclusionsThis method has the potential to segment structures of interest according to their texture in an unsupervised fashion, as well as to help analyze the deformation of tissues. Possible applications are not limited to US image. The same principle could also be applied to other medical imaging modalities such as MRI or CT scans.

Indexed as

DiaphragmEchocardiographyHeart VentriclesImage Processing, Computer-AssistedScoliosisAlgorithmsFractalsHumansMotionUltrasonographyFractal dimensionLandmarksTexture segmentationTissue motionUltrasound images

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.