Evidence map›Paper›PMID 39286719›Full record

ArticleCureus2024

Investigation of the Usefulness of Implants With Locking Mechanisms for Diffuse Idiopathic Skeletal Hyperostosis (DISH)-Induced Thoracic and Lumbar Fractures in Patients Operated in the Prone Position.

Seiya Watanabe, Kazuo Nakanishi, Kazuya Uchino, Hideaki Iba, Yoshihisa Sugimoto, Shigeru Mitani

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Seiya WatanabeOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.
Kazuo NakanishiOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.
Kazuya UchinoOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.
Hideaki IbaOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.
Yoshihisa SugimotoOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.
Shigeru MitaniOrthopaedics, Kawasaki Medical School, Kurashiki, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Diffuse idiopathic skeletal hyperostosis (DISH) is a disease that causes bone growth in the spine and musculoskeletal system, and even minor trauma can cause fractures that often require surgery. DISH-induced fractures show a tendency for bone loss when operated in the prone position, which can lead to poor fusion and implant failure; therefore, surgery in the lateral recumbent position is often recommended. However, inserting a pedicle screw (PS) in the lateral recumbent position is technically difficult. This study examined the effectiveness of the repair and fixation of thoracic and lumbar spine fractures using implants with locking mechanisms in the prone position in patients with DISH. Methods We retrospectively analyzed the data from 11 patients (six males and five females; mean age: 87 years) who underwent surgery for thoracic and lumbar fractures caused by DISH between December 2023 and June 2024. Surgery was performed in the prone position using PSs or transdiscal screws (TSDs) for DISH. Ennovate® implants manufactured by B-BRAUN were used. The fixed range was three above-three below for PSs and two above-two below for TSDs. The evaluation parameters were the height/level of injury, operative time, blood loss, local kyphosis angle, anterior wall height ratio, and complications. The local kyphosis angle was measured as the angle between the upper and lower endplates of the fractured vertebrae. The ratio of the anterior wall height was evaluated. Results The average operative time was 87 min (52-172 min), and the average blood loss was 40ml (10-140 ml). The preoperative and postoperative local kyphosis angle was -8.7° and -2.4°, respectively, and the average local kyphosis angle improvement was 6.3° (0.1-14°). The preoperative and postoperative anterior wall height ratio was 132% and 110%, respectively, and the average anterior wall height ratio improvement was 22% (2-82%). No complications, such as screw deviation, implant loosening, loss of correction, or skin problems, were observed. Conclusion This study demonstrated that DISH-induced thoracic and lumbar spine fractures could be repaired and fixed using implants with locking mechanisms in the prone position. The prone position is familiar to spine surgeons and is considered safe. Additionally, screw migration may occur due to decreased bone density in the vertebral bodies with DISH; in such cases, it would be better to fix the screw without forcing it to be repositioned.

Indexed as

dishimplants with locking mechanismslocal kyphosisposterior fusionprone position

Identifiers

PMID39286719
PMCPMC11404529

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.