ArticleScientific reports2024
Prediction of glaucoma progression by 24-h contact lens sensor profile in patients with normal-tension glaucoma.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Contemporary Research Questions in the Field of Contact Lenses and Where to Next?Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026Review
- Biodegradable Contact Lenses for Targeted Ocular Drug Delivery: Recent Advances, Clinical Applications, and Translational Perspectives.Molecules (Basel, Switzerland) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A single-center prospective cohort study was conducted to investigate whether intraocular pressure (IOP)-related 24-h contact lens sensor (CLS) profile parameters can help predict glaucoma progression in patients with normal-tension glaucoma (NTG). CLS measurements (Triggerfish; SENSIMED, Etagnières, Switzerland) at baseline without medication were performed for 24 h in one eye, following diurnal IOP measurements using Goldmann applanation tonometry at 3-h intervals. Glaucoma progression during the follow-up period of ≥ 2 years was determined based on the Guided Progression Analysis of Humphrey visual fields and/or structural progression using fundus photographs. Among 79 patients (mean values: follow-up periods, 48.1 months; age, 51.5 years; baseline IOP, 14.0 mmHg; mean deviation, - 6.04 dB), 23 showed glaucoma progression. A smaller standard deviation of nocturnal ocular pulse amplitude in the CLS profile, a larger range of diurnal IOP at baseline, and the presence of optic disc hemorrhage (DH) during the study period were significant risk factors for glaucoma progression in the multivariate Cox proportional hazards model (hazard ratio, 0.30/mVeq, 1.23/mmHg, and 4.37/presence of DH; P = 0.016, 0.017, and 0.001, respectively). CLS measurements may be useful for assessing the risk of future glaucoma progression in patients with NTG, providing supplementary information to routine IOP measurements.