Evidence map›Paper›PMID 39284678›Full record

ArticleBMJ open ophthalmology2024

Comparison of two digital alignment systems for toric intraocular lens implantation.

Johannes Zeilinger, Andreas Schlatter, Manuel Ruiss, Natascha Bayer, Martin Kronschläger, Oliver Findl

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in BMJ open ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05220683 (Comparing Two Digital Marking Systems), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05220683 naunknown statusnot on this map

Comparing Two Digital Marking Systems

TypeinterventionalSponsorVienna Institute for Research in Ocular SurgeryRan2021 to 2024Enrolled15ConditionsCataractArmsdigital marking system
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Johannes ZeilingerDepartment of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria.ORCID 0000-0001-8735-0342
Andreas SchlatterDepartment of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria.
Manuel RuissVienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria.
Natascha BayerVienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria.
Martin KronschlägerDepartment of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria.
Oliver FindlDepartment of Ophthalmology, Hanusch Hospital Vienna, Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Vienna, Austria oliver@findl.at.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the two most used digital alignment systems regarding precision, repeatability and loss of track.

methods15 eyes of 15 patients older than 21 years with cataracts were included in this prospective study. The two systems were intraoperatively superimposed and recorded, and the alignment of the two displayed alignment axes was analysed regarding precision, repeatability and loss of track.

resultsThere was a significant difference in precision and repeatability between the two digital alignment systems regarding the projected alignment axis. The deviation from the actual target axis was significantly different, with a mean of 0.34°±0.75° for the Zeiss system and 1.60°±1.08° for the Alcon system (p=0.03, n=14). The within-subject SD was significantly lower with 0.21° for the Zeiss system and 0.34° for the Alcon system (p=0.03, n=14).

conclusionsThe Zeiss Callisto system showed a significantly lower deviation from the target axis, higher stability with eye movements and less need for microscope illumination than the Alcon system. Both systems showed high precision when compared with manual marking methods. TRIAL REGISTRATION NUMBER: NCT05220683.

Indexed as

Lens Implantation, IntraocularAdultAgedAstigmatismCataractFemaleHumansLenses, IntraocularMaleMiddle AgedPhacoemulsificationProspective StudiesReproducibility of ResultsSurgery, Computer-AssistedVisual AcuityCataractImagingOcular surfaceTreatment SurgeryVision

Identifiers

PMID39284678
PMCPMC11409278

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.