Evidence map›Paper›PMID 39281122›Full record

ArticleQuantitative imaging in medicine and surgery2024

Deep learning-based reconstruction for 3-dimensional heavily T2-weighted fat-saturated magnetic resonance (MR) myelography in epidural fluid detection: image quality and diagnostic performance.

Mingyu Kim, Jisook Yi, Ho-Joon Lee, Seok Hahn, Yedaun Lee, Joonsung Lee

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mingyu KimDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Jisook YiDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.ORCID https://orcid.org/0000-0002-6633-0526
Ho-Joon LeeDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Seok HahnDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Yedaun LeeDepartment of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan, Republic of Korea.
Joonsung LeeGE HealthCare Korea, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Heavily T2-weighted fat-saturated (HT2W-FS) magnetic resonance myelography (MRM) is useful for diagnosing the cause of intracranial hypotension. Recently, deep learning-based reconstruction (DLR) has been utilized to improve image signal-to-noise ratios and sharpness while reducing artifacts, all without lengthening acquisition times. This study aimed to compare the diagnostic performance and image quality of conventional reconstruction (CR) and DLR of 3-dimensional (3D) HT2W-FS MRM applied to detecting epidural fluid in patients with clinically suspected intracranial hypotension. Methods: This retrospective study included 21 magnetic resonance myelography examinations using both CR and DLR in 21 patients who experienced orthostatic headache between April 2021 and September 2022. Quantitative image quality evaluation was performed by comparing signal-to-noise ratios at the lower thoracic levels. The image quality and artifacts were graded by three readers. The presence of epidural fluid was reported with a confidence score by two readers, and the area under the receiver operating curve, interobserver agreement, and inter-image-set agreement were evaluated. The conspicuity of the dura mater where the epidural fluid was detected was also investigated. Results: Quantitative and subjective image quality, and artifacts significantly improved with DLR (all P<0.001). Diagnostic performance of DLR was higher for both readers [reader 1: area under the curve (AUC) of CR =0.929; 95% confidence interval (CI): 0.902-0.950, AUC of DLR =0.965 (95% CI: 0.944-0.979), P=0.007; reader 2: AUC of CR =0.834 (95% CI: 0.798-0.866), AUC of DLR =0.877 (0.844-0.905), P=0.040]. Correlation with standard care of MRM in CR and DLR were both strong in reader 1 (rho =0.868-0.919, P<0.001), but was respectively strong and moderate in reader 2 (rho =0.734-0.805, P<0.001). Interobserver agreement was substantial (κ=0.708-0.762). The inter-image-set agreement was almost perfect for reader 1 (κ=0.907) and was substantial for reader 2 (κ=0.750). Dura mater conspicuity significantly improved with DLR (P<0.014, reader 1; P<0.001, readers 2 and 3). Conclusions: HT2W-FS magnetic resonance myelography with DLR demonstrates substantial improvements in image quality and may improve confidence in detecting epidural fluid.

Indexed as

deep learningIntracranial hypotensionmagnetic resonance imaging (MRI)myelography

Identifiers

PMID39281122
PMCPMC11400679

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.