Evidence map›Paper›PMID 39280962›Full record

ArticleJBJS essential surgical techniques

Tripod Fixation of Periacetabular Metastatic Lesions Using the IlluminOss Device.

Nicole L Levine, William C Eward, Brian Brigman, Alan Alper Sag, Julia D Visgauss

Abstract read
In one paragraph

Article in JBJS essential surgical techniques. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nicole L LevineDepartment of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina.ORCID https://orcid.org/0000-0002-9817-7722
William C EwardDepartment of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina.ORCID https://orcid.org/0000-0002-4553-1943
Brian BrigmanDepartment of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina.ORCID https://orcid.org/0000-0001-8851-8514
Alan Alper SagDepartment of Interventional Radiology, Duke University Medical Center, Durham, North Carolina.ORCID https://orcid.org/0000-0002-3106-0458
Julia D VisgaussDepartment of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina.ORCID https://orcid.org/0000-0002-0512-1763

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Percutaneous tripod fixation of periacetabular lesions is performed at our institution for patients with metastatic bone disease and a need for quick return to systemic therapy. We have begun to use the IlluminOss Photodynamic Bone Stabilization System instead of the metal implants previously described in the literature because of the success of the IlluminOss implant in fixing fragility fractures about the pelvis. Description: At our institution, the procedure is performed in the interventional radiology suite in order to allow for the use of 3D radiographic imaging and vector guidance systems. The patient is positioned prone for the transcolumnar PSIS-to-AIIS implant and posterior column/ischial tuberosity implant or supine for the anterior column/superior pubic ramus implant. Following a small incision, a Jamshidi needle with a trocar is utilized to enter the bone at the chosen start point. A hand drill is utilized to advance the Jamshidi needle according to the planned vector; alternatively, a curved or straight awl can be utilized. The 1.2-mm guidewire is placed and reamed. We place both the transcolumnar and posterior column wires at the same time to ensure that there is no interference. The balloon catheter for the IlluminOss is assembled on the back table and inserted according to the implant technique guide. The balloon is inflated and observed on radiographs in order to ensure that the cavity is filled. Monomer is then cured, and the patient is flipped for the subsequent implant. Following placement of the 3 IlluminOss devices, adjunct treatments such as cement acetabuloplasty or cryoablation can be performed. Alternatives: Alternative treatments include traditional open fixation of impending or nondisplaced acetabular fractures in the operating room, or percutaneous implant placement in the operating room. Implant placement may be performed with the patient in the supine, lateral, or prone position, depending on surgeon preference. Alternative implants include standard metal implants such as plates and screws, or cement augmentation either alone or with percutaneous screws. Finally, ablation alone may be an alternative option, depending on tumor histology. Rationale: Open treatment of acetabular fractures is a more morbid procedure, given the larger incision, increased blood loss, longer time under anesthesia, and increased length of recovery. Percutaneous fixation may be performed in either the operating room or interventional radiology suite, depending on the specific equipment setup at an individual institution. At our institution, we prefer utilizing the interventional radiology suite as it allows for more precise implant placement through the use of an image-based vector guidance system and 3D fluoroscopy to accurately identify safe corridors. The use of percutaneous fixation allows for faster recovery and earlier return to systemic therapy. Because the IlluminOss implant is radiolucent, it allows for better evaluation of disease progression and can better accommodate nonlinear corridors or fill a lytic lesion to provide stability. Expected Outcomes: Postoperatively, we expect the patient to be weight-bearing as tolerated with use of an assistive device. We expect the small incisions to fully heal within 2 weeks. Patients should be able to return to systemic therapy as indicated earlier than with an open procedure. Important Tips: The use of a hand drill with the Jamshidi needle and trocar can help adjust a drilled pathway and allow for close adherence to a planned vector.Vector guidance systems can be useful to fully capture the area at risk for fracture and to provide maximal stability with the expandable implant, but they are not necessary to perform the procedure.Placing both posterior implants at the same time can be helpful to avoid interference. This is accomplished by drilling and placing the guidewire for both implants prior to reaming and placing the balloon implant. Acronyms and Abbreviations: CT = Computed tomographyPSIS = posterior superior iliac spineAIIS = anterior inferior iliac spine.

Identifiers

PMID39280962
PMCPMC11392467

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.