Evidence map›Paper›PMID 39280152›Full record

ArticleJSES international2024

Quantifying bone loss and lateralization with standardized baseplate versus augmented baseplates.

Anup Shah, Brian Werner, Rueben Gobezie, Patrick Denard, Samuel Harmsen, Tyler Brolin, Michael Bercik, Siddhant Thankur, Scott Doody, David Knopf and 2 more

Abstract read
In one paragraph

Article in JSES international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Anup ShahDepartment of Orthopedic Surgery, University of Arizona, College of Medicine - Phoenix, Phoenix, AZ, USA.
Brian WernerDepartment of Orthopedic Surgery, University of Virginia, Charlottsville, VA, USA.
Rueben GobezieDepartment of Orthopedic Surgery, Cleveland Shoulder Institute, Cleveland, OH, USA.
Patrick DenardDepartment of Orthopedic Surgery, Oregon Shoulder Institute, Medford, OR, USA.
Samuel HarmsenDepartment of Orthopedic Surgery, Banner Health, Phoenix, AZ, USA.
Tyler BrolinDepartment of Orthopedic Surgery, Campbell Clinic, Memphis, TN, USA.
Michael BercikDepartment of Orthopedic Surgery, Lancaster Orthopedic Group, Lancaster, PA, USA.
Siddhant ThankurDepartment of Orthopedic Surgery, Arthex, Inc, Naples, FL, USA.
Scott DoodyDepartment of Orthopedic Surgery, Arthex, Inc, Naples, FL, USA.
David KnopfDepartment of Orthopedic Surgery, Arthex, Inc, Naples, FL, USA.
Nick MetcalfeDepartment of Orthopedic Surgery, Arthex, Inc, Naples, FL, USA.
Evan LedermanDepartment of Orthopedic Surgery, University of Arizona, College of Medicine - Phoenix, Phoenix, AZ, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Reverse shoulder arthroplasty continues to be utilized for the treatment of cuff tear arthropathy, glenohumeral degenerative joint disease, and irreparable rotator cuff tears. With advancement in component designs, glenoid retroversion and inclination are now correctable with augmented baseplates. However, quantifying bone loss and lateralization compared to standard baseplates has not been studied. The purpose of the current study is to determine the volume of bone reamed and net lateralization with a standardized baseplate vs. augmented baseplate when glenoid inclination was corrected to neutral. Methods: A series of 21 computed tomography scans of patients presenting for shoulder arthroplasty were chosen based on a range of increasing native positive inclination. Computed tomography scans were uploaded into segmentation software and processed. Four fellowship trained shoulder surgeons were then blinded from each other and virtually placed a neutral baseplate and an augmented baseplate for each specimen. Baseplate position was standardized. Additionally, baseplate backside seating of a minimum of 80% was also standardized and glenosphere (nonlateralized) size was selected to eliminate variation in baseplate contact and position. Glenoid inclination was corrected to a minimal of neutral in each specimen as well as glenoid retroversion corrected to <10 Results: The mean glenoid retroversion was 8.1 Conclusion: The current study demonstrates approximately 50% less bone removal and 2.4 mm of true lateralization with a 10-degree augmented baseplate when compared to standard baseplates.

Indexed as

Augmented baseplateBaseplate positionGlenoid bone lossGlenoid inclinationReverse shoulder angleReverse shoulder arthroplasty

Identifiers

PMID39280152
PMCPMC11401572

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.