Evidence map›Paper›PMID 39280143›Full record

ArticleJSES international2024

Optimizing stability and motion in reverse shoulder arthroplasty with a 135° neck-shaft-angle: a computer model study of standard versus retentive humeral inserts.

Stefan Bauer, William G Blakeney, Xavier Lannes, Allan W Wang, Wei Shao

Abstract read
In one paragraph

Article in JSES international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stefan BauerCentre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland.
William G BlakeneySchool of Surgery, University of Western Australia, Perth, WA, Australia.
Xavier LannesCentre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland.
Allan W WangSchool of Surgery, University of Western Australia, Perth, WA, Australia.
Wei ShaoCentre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: There has been a trend to shift from a 155° and 145° neck-shaft-angle (NSA) to a more "anatomical" reverse shoulder arthroplasty with less distalization and a 135° NSA. Multiple studies have shown that a 135° NSA is beneficial for motion. There are some concerns about primary implant stability with a 135° NSA. When instability is detected, increasing the tension with thicker inlays or changing the NSA to 145° are possible solutions. A retentive 135° (Ret135) inlay may be an alternative to avoiding increased distalization; however, retentive liners are widely regarded as salvage options reducing range of motion (ROM) and avoided by most surgeons. The hypothesis of this study was that a retentive 135° insert of the tested implant system may not have drawbacks for impingement-free ROM compared to a standard 145° insert (Sta145). Methods: In this computer model study, 22 computed tomographic scans (11 males/11 females) were used to create models with a constant humeral stem (Perform/Stryker) and +3 mm lateralized baseplate +36 mm glenosphere for females and +6 mm lateralized baseplate +39 mm glenosphere for males using Blueprint software (Imascap, Brest, France). A Ret135, standard 135° (Sta135), and Sta145 (+10°) insert were compared for adduction (ADD), extension (EXT), external rotation (ER), and internal rotation (IR) all with the arm at the side as well as for combined IR (CIR = EXT + IR) and combined notching relevant (CNR) ROM (EXT + ER + IR + ADD). Results: Sta135 showed significantly better ROM for ER, IR, ADD, EXT, CNR ROM, and CIR compared to Ret135 ( Conclusion: For this implant system tested in a computer model, a 135° standard liner offers the best ROM. A 135° retentive liner maintains at least equivalent CIR and motion to prevent notching compared to a standard 145° liner. 135° retentive liners are more than salvage options and may help to prevent distalization and overtensioning by increased liner thickness.

Indexed as

ImpingementNeck shaft angleNotchingRange of motionRetentive linerReverse shoulder arthroplasty

Identifiers

PMID39280143
PMCPMC11401560

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.