Evidence map›Paper›PMID 39279031›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2025

Mechanically compliant locking plates for diaphyseal fracture fixation: A biomechanical study.

Connor Huxman, Gregory Lewis, April Armstrong, Gary Updegrove, Zachary Koroneos, Jared Butler

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Finite element andFrontiers in bioengineering and biotechnology · 2026
    Article
  4. Article
  5. Article
  6. Effects of Plate-Bone Contact on Bridge Plate Fracture Fixation Biomechanics: Computational, Experimental, and Analytical Modeling.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
  7. Article
  8. Mechanically compliant locking plates for diaphyseal fracture fixation: A biomechanical study.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Connor HuxmanDepartment of Mechanical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA.ORCID 0000-0002-4526-2771
Gregory LewisDepartment of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA.ORCID 0000-0002-3673-0182
April ArmstrongDepartment of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA.ORCID 0000-0003-3729-9811
Gary UpdegroveDepartment of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA.ORCID 0000-0002-1594-7411
Zachary KoroneosDepartment of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA.ORCID 0000-0002-7645-8179
Jared ButlerSchool of Engineering Design and Innovation, The Pennsylvania State University, University Park, Pennsylvania, USA.ORCID 0000-0003-3526-9678

Funding

Penn State Clinical and Translational Science InstituteUL1TR002014 · NCATS · PENNSYLVANIA STATE UNIV HERSHEY MED CTR · PI KRASCHNEWSKI, JENNIFER L. · 2016 to 2025
$33.7M
NCATS NIH HHS UL1 TR002014The Pennsylvania State University, Diefenderfer Graduate Fellowship in Entrepreneurship
6 · The paper itself

Abstract

Axial micromotion between bone fragments can stimulate callus formation and fracture healing. In this study, we propose a novel mechanically compliant locking plate which achieves up to 0.6 mm of interfragmentary motion as flexures machined into the plate elastically deflect under physiological load. We investigated the biomechanical performance of three compliant plate variations in comparison to rigid control plates with small and large working lengths in a comminuted bridge plating scenario using humeral diaphysis surrogates. Under static axial loading, average interfragmentary motion was 6 times larger at 100 N (0.38 vs. 0.05 mm) and nearly three times larger at 350 N (0.58 vs. 0.2 mm) for compliant plates than rigid plates, respectively. Compliant plates delivered between 2.5 and 3.4 times more symmetric interfragmentary motion than rigid plates (p < 0.01). The bi-phasic stiffness of compliant pates provided 74%-96% lower initial axial stiffness up to approximately 100 N (p < 0.01), after which compliant plate stiffness was similar to rigid plates with increased working length (p > 0.3). The strength to failure of compliant plates under dynamic loading was on average 48%-55% lower than rigid plate groups (p < 0.01); however, all plates survived cyclic fatigue loading of 100,000 cycles at 350 N. This work characterizes the improvement in interfragmentary motion and the reduction in strength to failure of compliant plates compared to control rigid plates. Compliant plates may offer potential in comminuted fracture healing due to their ability to deliver symmetric interfragmentary motion into the range known to stimulate callus formation while surviving moderate fatigue loading with no signs of failure.

Indexed as

Bone PlatesDiaphysesBiomechanical PhenomenaFracture Fixation, InternalHumansHumeral FracturesMaterials Testingbridge platingcompliant mechanismsdynamic platingfracture fixation

Identifiers

PMID39279031
PMCPMC11615426

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.