ArticleCancer imaging : the official publication of the International Cancer Imaging Society2024

Effects of tube voltage, radiation dose and adaptive statistical iterative reconstruction strength level on the detection and characterization of pulmonary nodules in ultra-low-dose chest CT.

Yue Yao, Xuan Su, Lei Deng, JingBin Zhang, Zengmiao Xu, Jianying Li, Xiaohui Li

Abstract read
In one paragraph

Article in Cancer imaging : the official publication of the International Cancer Imaging Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yue YaoDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China.
Xuan SuDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China.
Lei DengDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China.
JingBin ZhangDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China.
Zengmiao XuDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China.
Jianying LiGE HealthCare, Beijing, China.
Xiaohui LiDepartment of Radiology, the second Affiliated Hospital, Xi'an Jiaotong University, Xi'an, China. Li_xiaohui568@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo explore the effects of tube voltage, radiation dose and adaptive statistical iterative reconstruction (ASiR-V) strength level on the detection and characterization of pulmonary nodules by an artificial intelligence (AI) software in ultra-low-dose chest CT (ULDCT). MATERIALS AND

methodsAn anthropomorphic thorax phantom containing 12 spherical simulated nodules (Diameter: 12 mm, 10 mm, 8 mm, 5 mm; CT value: -800HU, -630HU, 100HU) was scanned with three ULDCT protocols: Dose-1 (70kVp:0.11mSv, 100kVp:0.10mSv), Dose-2 (70kVp:0.34mSv, 100kVp:0.32mSv), Dose-3 (70kVp:0.53mSv, 100kVp:0.51mSv). All scanning protocols were repeated five times. CT images were reconstructed using four different strength levels of ASiR-V (0%=FBP, 30%, 50%, 70%ASiR-V) with a slice thickness of 1.25 mm. The characteristics of the physical nodules were used as reference standards. All images were analyzed using a commercially available AI software to identify nodules for calculating nodule detection rate (DR) and to obtain their long diameter and short diameter, which were used to calculate the deformation coefficient (DC) and size measurement deviation percentage (SP) of nodules. DR, DC and SP of different imaging groups were statistically compared.

resultsImage noise decreased with the increase of ASiR-V strength level, and the 70 kV images had lower noise under the same strength level (mean-value 70 kV: 40.14 ± 7.05 (dose 1), 27.55 ± 7.38 (dose 2), 23.88 ± 6.98 (dose 3); 100 kV: 42.36 ± 7.62 (dose 1); 30.78 ± 6.87 (dose 2); 26.49 ± 6.61 (dose 3)). Under the same dose level, there were no differences in DR between 70 kV and 100 kV (dose 1: 58.76% vs. 58.33%; dose 2: 73.33% vs. 70.83%; dose 3: 75.42% vs. 75.42%, all p > 0.05). The DR of GGNs increased significantly at dose 2 and higher (70 kV: 38.12% (dose 1), 60.63% (dose 2), 64.38% (dose 3); 100 kV: 37.50% (dose 1), 59.38% (dose 2), 66.25% (dose 3)). In general, the use of ASiR-V at higher strength levels (> 50%) and 100 kV provided better (lower) DC and SP.

conclusionDetection rates are similar between 70 kV and 100 kV scans. The 70 kV images have better noise performance under the same ASiR-V level, while images of 100 kV and higher ASiR-V levels are better in preserving the nodule morphology (lower DC and SP); the dose levels above 0.33mSv provide high sensitivity for nodules detection, especially the simulated ground glass nodules.

Indexed as

Multiple Pulmonary NodulesPhantoms, ImagingRadiation DosageTomography, X-Ray ComputedHumansImage Processing, Computer-AssistedLung NeoplasmsRadiographic Image Interpretation, Computer-AssistedRadiography, ThoracicSolitary Pulmonary NoduleDetectionIterative reconstructionPulmonary noduleULDCT